Flow Control Valves<br />

FULLY ADJUSTABLE NEEDLE<br />

2<br />

1<br />

<strong>Cartridge</strong> Dimensions<br />

Maximum<br />

Nominal<br />

Orifice<br />

Typical<br />

<strong>Cartridge</strong><br />

Model Code<br />

Cavity a b<br />

L<br />

c<br />

H K<br />

Installation<br />

Torque<br />

(Nm)<br />

4,0 mm dia. NFBC – LCN T - 162A 31,0 19,1 40,4 - 43,9 35 - 40<br />

4,8 mm dia. NFCC – LCN T - 13A 35,0 22,2 57,7 63,2 63,5 45 - 50<br />

6,4 mm dia. NFDC – LAN T-5A 41,4 28,6 59,7 71,6 69,3 60 - 70<br />

9,7 mm dia. NFEC – LEN T - 16A 62,0 31,8 67,6 77,7 74,7 200 - 215<br />

14,2 mm dia. NFFC – LGN T - 18A 79,5 41,3 84,1 88,9 88,1 465 - 500<br />

NFBC NFCC NFDC NFEC NFFC<br />

Q = L/min.<br />

20<br />

15<br />

10<br />

5<br />

0<br />

Full Adjustment 5 Turns<br />

- +<br />

b<br />

2<br />

Controlled<br />

Flow<br />

1<br />

Controlled Flow<br />

Performance Curves<br />

LCN<br />

c<br />

a<br />

1 2 3 4 5<br />

Number of Turns<br />

Locating<br />

Shoulder<br />

Q = L/min.<br />

40<br />

30<br />

20<br />

10<br />

0<br />

LCN<br />

LDN<br />

1 2 3 4 5<br />

Number of Turns<br />

Adjustment Sensitivity at 7 bar Differential<br />

Q = L/min.<br />

■ Maximum operating pressure = 350 bar.<br />

80<br />

60<br />

40<br />

20<br />

0<br />

1 2 3 4 5<br />

Number of Turns<br />

■ Because needle valves are non-compensating devices, the fixed orifice size will regulate flow through<br />

the valve in proportion to the square root of the pressure differential across ports 1 and 2.<br />

■ The sharp edged orifice design minimizes flow variations due to viscosity changes.<br />

■ There is no leakage when the adjustment mechanism is turned to the shut-off position.<br />

OPTION ORDERING INFORMATION<br />

NF ✱ C – ✱ ✱ ✱<br />

Maximum<br />

Nominal<br />

Orifice<br />

Control** Maximum Orifice Diameter Seal Material<br />

B 4,0 mm dia. L Standard Screw NFBC N Buna-N<br />

Adjustment C 4 mm<br />

C 4,8 mm dia. V Viton<br />

H* Calibrated NFCC<br />

D 6,3 mm dia. Handknob with C 4,8 mm<br />

Detent Lock D 2,3 mm<br />

E 9,6 mm dia.<br />

K Handknob NFDC<br />

F 14,2 mm dia. with Lock Knob<br />

* Not Available<br />

A 6,4 mm<br />

B 3,0 mm<br />

on NFBC NFEC<br />

E 9,7 mm<br />

F 7,1 mm<br />

NFFC<br />

G 14,2 mm<br />

H 9,6 mm<br />

1 2 3 4 5<br />

Number of Turns<br />

Consult the Sun website for<br />

** See page 178 our most recent and complete<br />

for information information on the full Corrosion<br />

on Control Options Resistant line of products.<br />

Visit www.sunhydraulics.com for current list pricing and complete technical information on all Sun products.<br />

LAN<br />

LBN<br />

Q = L/min.<br />

160<br />

120<br />

80<br />

40<br />

0<br />

LEN<br />

LFN<br />

80 Int’l <strong>Shortcut</strong> <strong>Catalogue</strong> #999-901-312<br />

Q = L/min.<br />

320<br />

240<br />

160<br />

80<br />

0<br />

LGN<br />

LHN<br />

1 2 3 4 5<br />

Number of Turns