Relief Valves<br />
PILOT OPERATED, BALANCED PISTON, VENTABLE WITH EXTERNAL DRAIN<br />
Full Adjustment 5 Turns<br />
+ -<br />
b<br />
4<br />
Drain<br />
3<br />
Vent<br />
2<br />
Outlet<br />
Inlet<br />
1<br />
P = bar<br />
P = bar<br />
350<br />
300<br />
250<br />
200<br />
150<br />
100<br />
50<br />
15<br />
10<br />
5<br />
4<br />
0 50 100 150 200<br />
Flow = L/min.<br />
0<br />
c<br />
a<br />
Locating<br />
Shoulder<br />
A<br />
B<br />
D & E<br />
C & W<br />
20 40 60<br />
Flow = L/min.<br />
2 1<br />
3<br />
<strong>Cartridge</strong> Dimensions<br />
Capacity<br />
Typical<br />
<strong>Cartridge</strong><br />
Model Code<br />
Cavity a b<br />
L<br />
c<br />
C K<br />
Installation<br />
Torque<br />
(Nm)<br />
60 L/min. RVCD – LAN T - 21A 35,1 22,2 78,5 82,6 84,8 45 - 50<br />
120 L/min. RVED – LAN T - 22A 35,1 28,6 87,4 89,0 93,7 60 - 70<br />
240 L/min. RVGD – LAN T - 23A 46,0 31,8 99,8 101,3 106,4 200 - 215<br />
480 L/min. RVID – LAN T - 24A 63,5 41,8 121,4 126,7 127,8 465 - 500<br />
Performance Curves<br />
RVCD RVED RVGD RVID<br />
80<br />
P = bar<br />
P = bar<br />
350<br />
300<br />
250<br />
200<br />
150<br />
100<br />
50<br />
15<br />
10<br />
5<br />
0<br />
A<br />
B<br />
C & W<br />
D & E<br />
40 80 120<br />
Flow = L/min.<br />
160<br />
P = bar<br />
100 200 300<br />
Flow = L/min.<br />
■ Maximum operating pressure = 350 bar.<br />
■ Maximum valve leakage at 24 cSt = RVCD: 30 cc/min. at 70 bar; RVED: 50 cc/min. at 70 bar;<br />
RVGD: 65 cc/min. at 70 bar; RVID: 80 cc/min. at 70 bar.<br />
■ Control pilot flow = RVCD: 0,11 to 0,16 L/min.; RVED: 0,16 to 0,25 L/min.; RVGD, RVID: 0,25 to 0,33 L/min.<br />
■ Typical response time 10 ms.<br />
■ Factory pressure setting established at 15 L/min.<br />
■ Pressure at port 4 is directly additive to the valve setting at a 1:1 ratio and should not exceed 350 bar.<br />
■ Will accept maximum pressure at port 2; suitable for use in cross-port relief circuits.<br />
OPTION ORDERING INFORMATION<br />
0 100 200 300 400<br />
Flow = L/min.<br />
Typical Pressure Rise<br />
P = bar<br />
RV ✱ D – ✱ ✱ ✱<br />
Nominal<br />
Capacity<br />
Control** Adjustment Range Seal Material<br />
C 60 L/min. L Standard Screw A 7 - 210 bar N Buna-N<br />
Adjustment Standard set at 70 bar<br />
E 120 L/min. C* Tamper Resistant B 3,5 - 105 bar<br />
V Viton<br />
Factory Set Standard set at 70 bar<br />
G 240 L/min. K Handknob C 10,5 - 420 bar<br />
with Lock Knob Standard set at 70 bar<br />
I 480 L/min. * Special setting required. D 1,7 - 55 bar<br />
Specify at time of order. Standard set at 30 bar<br />
** See page 178 E 1,7 - 28 bar<br />
for information Standard set at 14 bar<br />
on Control Options<br />
W 10,5 - 315 bar<br />
Customer specified special<br />
setting stamped on hex.<br />
Standard set at 70 bar<br />
Visit www.sunhydraulics.com for current list pricing and complete technical information on all Sun products.<br />
350<br />
300<br />
250<br />
200<br />
150<br />
100<br />
50<br />
Vented Pressure<br />
15<br />
10<br />
5<br />
0 200 400 600 800<br />
Flow = L/min.<br />
0<br />
A<br />
B<br />
D & E<br />
C & W<br />
400<br />
P = bar<br />
P = bar<br />
350<br />
300<br />
250<br />
200<br />
150<br />
100<br />
50<br />
15<br />
10<br />
5<br />
0 400 800 1200 1600<br />
Flow = L/min.<br />
200 400 600<br />
Flow = L/min.<br />
22 Int’l <strong>Shortcut</strong> <strong>Catalogue</strong> #999-901-312<br />
0<br />
A<br />
D & E<br />
C & W<br />
B<br />
800