12.07.2015 Views

Temperature Transmitters TF02/TF02-Ex (head mounted) and ...

Temperature Transmitters TF02/TF02-Ex (head mounted) and ...

Temperature Transmitters TF02/TF02-Ex (head mounted) and ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Fieldbus CommunicationParameter(Access r = read/w = write)ST_REVrTAG_DESCr / wSTRATEGYr / wALERT_KEYr / wMODE_BLKr / wBLOCK_ERRrRS_STATErTEST_RWr/wDD_RESOURCErMANUFAC_IDrDEV_TYPErDEV_REVrDD_REVrGRANT_DENYrHARD_TYPESrRESTARTr / wFEATURESrFEATURES_SELr / wDescriptionRevision of static (NV) data. The revision counter is incremented at every write accessto static data in this block.A user defined text can be applied to this block for further referencing (TAG name).Allows grouping of several blocks by applying the same value for these blocksAn identification number can be entered. With this value a host system is able to sortor group alarms or events.Contains three sub collections with the same structure, "Actual" for actual state, "Permitted"for the allowed state for this block <strong>and</strong> "Normal“ for normal mode.AUTOThe operation of the AI blocks is enabledO/SThe operation of the AI blocks is disabledSIMULATE_ACTIVE Simulation enabledOUT_OF_SERVICE Block mode is O/S (Out of Service)LOST_STATIC_DATA Loss of data in NV memoryONLINENormal operation mode. Block is in AUTO stateSTANDBYResource block is in O/S stateONLINE_LINKING Connecting of communication links between the functionblocks is in processOnly used for certification of FF devices, not used for normal operation.Delivers information about the device description, used for configuration tools.Manufacturer ID, ABB = 0x000320Device ID, <strong>TF02</strong> = 30 (decimal)Revision number of the deviceRevision number of the device descriptionUsed for access control (to field device by host)Indicates the types of hardware that are available to this resource. If an I/O block isconfigured that requires a type of hardware that is not available, the result will be ablock alarm for a configuration error.RUNPassive state (no change)RESOURCE Clear up problems like garbage collection.DEFAULTS Restart all configurable function block application objectsto their initial value.PROCESSOR Same as a hardware reset of the device.This value can not be read out.Displays the additional features supported by the device.Selection of the additional features.Following features are supported:REPORTS:Enables alarms. Must be set for alarming at work.FAULTSTATE:not relevantOUT READBACK: not relevant18 <strong>Temperature</strong> <strong>Transmitters</strong> <strong>TF02</strong>/<strong>TF02</strong>-<strong>Ex</strong> (<strong>head</strong> <strong>mounted</strong>) <strong>and</strong> TF202/TF202-<strong>Ex</strong> (field <strong>mounted</strong>) 42/11-51 EN

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!