Fieldbus CommunicationParameter(Access r = read/w = write)sensor_sn_1rsensor_cal_method_1r/wsensor_cal_loc_1r/wsensor_cal_date_1r/wsensor_cal_who_1r/wsensor_connection_1r/wprimary_value_type_2rprimary_value_2rprimary_value_range_2rcal_point_hi_2r/wcal_point_lo_2r/wcal_min_span_2rcal_unit_2rsensor_type_2r/wsensor_range_2rsensor_sn_2rsensor_cal_method_2r/wsensor_cal_loc_2r/wsensor_cal_date_2r/wsensor_cal_who_2r/wSecondary Valuersecondary value unitr/wModule Serial NumberrDescriptionSerial number of the sensor 1.Either the factory trimmed calibration data or a user trimmed calibration datacan be selected.The last location of the sensor calibration (channel 1).Optional date of user trimmed calibration can be entered.Optional personal of user trimmed calibration can be entered.Any resistor type can be connected with 2, 3 or 4 wires.A connection with more than 2 wires disables channel 2 automatically.Shows the characteristic of the primary value 2 (channel 2).Can be a process / or noon process value. Is determined by the selected sensortype.Only the linear voltage or resistor types produce a non process value.Actual value (<strong>and</strong> its status) of channel 2Shows the sensor dependent range of the channel value (output) forchannel 2.The value of the Secondary Value (channel 2) measurement used for thehigh calibration point.The value of the Secondary Value (channel 2) measurement used for the lowcalibration point.The minimum span that must be used between the high <strong>and</strong> low calibrationpoints (sensor 2).The unit used for the calibration input.Choose the sensor type for channel 2.Can be either one of the FF st<strong>and</strong>ard types or a non st<strong>and</strong>ard type. In caseof the "non st<strong>and</strong>ard" type is selected, the parameter sensor non st<strong>and</strong>ard 2determines the type.Shows the sensor range (in Ohm or mV) of channel 2.Serial number of the sensor 2Either the factory trimmed calibration data or a user trimmed calibration datacan be selected.The last location of the sensor calibration (channel 2).Optional date of user trimmed calibration can be entered.Optional personal of user trimmed calibration can be entered.Shows the characteristic of the primary value 1 (channel 1).Can be a process / or noon process value. Is determined by the selected sensortype.Only the linear voltage or resistor types produce a non process value.Determines the unit of the secondary value output of the Transducer Block.The value is the CJC.Serial number of the device24 <strong>Temperature</strong> <strong>Transmitters</strong> <strong>TF02</strong>/<strong>TF02</strong>-<strong>Ex</strong> (<strong>head</strong> <strong>mounted</strong>) <strong>and</strong> TF202/TF202-<strong>Ex</strong> (field <strong>mounted</strong>) 42/11-51 EN

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!