12.07.2015 Views

Catalog - PIKE Technologies

Catalog - PIKE Technologies

Catalog - PIKE Technologies

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Selection of the digital control module, PC control includes <strong>PIKE</strong>TempPRO software for graphical setup and automated data collectionfor thermal experimentsTemperature controlled crystal plates are available for thermalstudy of materials. <strong>PIKE</strong> <strong>Technologies</strong> offers temperature controllerswith digital and PC programmable set points.The GladiATR high performance diamond ATR is available inconfigurations to fit most FTIR spectrometers.ATR/FTIR spectra from cure of thermoset epoxy using the heated diamondcrystal plate on the GladiATRG L A D IATR A C C E S S O RY S P E C I F I C AT I O N SATR Crystal Choices Diamond, germaniumCrystal Plate Mounting User changeable platesCrystal TypeMonolithicDiamond Mounting BrazedCrystal Plate Mounts Stainless steelAngle of Incidence 45 degrees, nominalCrystal Dimensions, Surface 3.0 mm diameterOpticsAll reflectivePressure DeviceRotating, continuously variable pressure;click stop at maximumDigital Force Adapter Load cell sensor for precise and reproducible(option)pressure control. Attaches directly toGladiATR clamp. Digital readout.Maximum Pressure 30,000 psiSample Access80 mm, ATR crystal to pressure mountSpectral Range, Diamond 4000 to 30 cm -1 (IR optics dependent)Heating OptionsDiamond, 210 or 300 ºC maximumAccuracy +/- 0.5%Sensor Type3 wire Pt RTD (low drift, high stability)Temperature Control Digital or digital with PC control (up to10 ramps, automated data collection,USB interface)Input Voltage100–240 VAC, auto setting, external powersupply; 110/220 VAC switchable (300 °C version)Operating Voltage 4A/24 VDC, 100 W6A/24 VAC, 150 W (300 °C version)Cooling OptionsLiquid jacketed crystal plates availableSpecular Reflection Option Optional, 45 degree nominal angle of incidencePurge SealingPurge tubes and purge line connector includedAccessory Dimensions 140 x 205 x 340 mm(W x D x H) (excludes FTIR baseplate and mount)FTIR Compatibility Most, specify model and typeGladiATR Base Optics (must select, insert spectrometer model for XX)P A R T N U M B E R026-18XXD E S C R I P T I O NGladiATR Single Reflection ATR Base Optics, with heatingcapability up to 210 °C026-17XX GladiATR 300 Single Reflection ATR Base Optics, 300 °CNotes: All GladiATRs include purge tubes, purge kit, and selected spectrometer basemount. GladiATR 300 is configured and available only with the Diamond plate.Crystal plates for the basic model (026-18XX) must be selected from the table below.High-Pressure Clamp, Digital Force Adapter and Liquids Retainer/Volatiles Cover areoptional and need to be ordered separate, if required.GladiATR Stainless Top (must select one or more)P A R T N U M B E RD E S C R I P T I O N026-2001 GladiATR Standard Stainless Top026-2002 GladiATR Heated Stainless Top026-2003 GladiATR Liquid Jacketed Stainless TopNotes: Stainless top is not required for 300 °C version.GladiATR Crystal Plates for GladiATR (must select one or more)P A R T N U M B E RD E S C R I P T I O N026-2100 Diamond Crystal Plate026-2050 Ge Crystal Plate026-2200 Specular Reflection PlateNotes: GladiATR Crystal Plates are pre-aligned and pinned-in-place. Changing crystalplates is easy and fast to optimize sampling results.GladiATR Pressure Clamp, all models (must select for solid or powdered samples)P A R T N U M B E RD E S C R I P T I O N026-3020 High-Pressure Clamp076-6026 Digital Force Adapter for High-Pressure ClampNotes: The High-Pressure Clamp is required for analysis of solids, powders and useof liquids retainer and/or Digital Force Adapter (Digital Force Adapter cannot beused with heated crystal plates). Pressure clamp includes a flat tip, a swivel tip anda concave tip.GladiATR Temperature Controlled Crystal PlatesP A R T N U M B E RD E S C R I P T I O N026-4102 Heated Diamond Crystal Plate, 300 °C (GladiATR 300 only)026-4100 Heated Diamond Crystal Plate, 210 °C026-4050 Heated Ge Crystal Plate, 130 °C026-4110 Liquid Jacketed Diamond Crystal Plate026-4150 Liquid Jacketed Ge Crystal Plate, 130 °C076-1220 Digital Temperature Control Module, 210 °C076-1420 Digital Temperature Control Module, PC Control, 210 °C076-1210 Digital Temperature Control Module, 300 °C076-1410 Digital Temperature Control Module, PC Control, 300 °CNotes: For heated diamond crystal plates, maximum crystal temperature is 300 or210 °C, depending on the GladiATR model selected. Ge becomes optically opaque at190 °C. Max recommended temperature for this crystal is 130 °C. Temperaturecontroller is required for heated crystal plates. Digital temperature controller,PC control includes <strong>PIKE</strong> TempPRO software. Liquid jacketed crystal plates requirecustomer provided circulator.GladiATR Sampling OptionsP A R T N U M B E RO R D E R I N G I N F O R M A T I O ND E S C R I P T I O N026-5012 Flow-Through Attachment, 210 °C, sample volume 100 µL026-5014 Flow-Through Attachment, 300 °C, sample volume 100 µL026-5013 Liquids Retainer and Volatiles Cover Set026-5015 Liquids Retainer and Volatiles Cover Set, 300 °C026-5010 Liquids Retainer for Performance Plates, 260 °C026-3051 Volatiles Cover for Performance PlatesNotes: Flow-Through Attachment, Liquids Retainer and Volatiles Cover are compatiblewith all crystal offerings (require High-Pressure Clamp).A T T E N U A T E D T O T A L R E F L E C T A N C E – L I Q U I D S , S O L I D S A N D I N - B E T W E E N13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!