Spectroelectrochemical cell with removable and interchangeable crystalsmounted on the VeeMAXVeeMAX spectroelectrochemical cell offers maximum flexibility by itsinterchangeable and removable crystalsMotorized control of angle of incidence via personal computerfor automated data collection of depth profiling studies and ATRmeasurements is available for the accessory. The motorizedVeeMAX III is ideal for depth profiling studies as it greatly speedsand improves the precision and reproducibility of the datacollection process.AutoPRO Software controlof VeeMAX III angle ofincidence (automatedpolarizer available) forautomated depth profilingstudies, angle of incidenceand polarization anglecan be set independently.V E EMAX III W I T H ATR S P E C I F I C AT I O N SVeeMAX withATR opticallayoutATR Crystal Choice ZnSe, Ge, Si, ZnSCrystal Plate Mounting User changeable platesCrystal Plate Mounts Stainless SteelCrystal Dimension, Surface 20 mm diameterOpticsAll reflectivePressure DeviceRotating, continuous variable pressure;click stop at maximumHeating Options 130 °CAccuracy +/- 0.5%Sensor Type3 wire Pt RTD (low drift, high stability)Temperature Control Digital or digital with PC control (up to 10 ramps,automated data collection, USB interface)Input Voltage100–240 VAC, auto setting, externalpower supplyOperating Voltage 24 VDC/50 WPurge SealingPurge tubes and purge barb includedAccessory Dimensions 177 x 92 x 162 mm (excludes clamp(W x D x H) height and baseplate)SpectroelectrochemicalVessel Dimensions 19 mm diameter tapering to 25 mm, 25 mm tallSpectroelectrochemicalVessel Volume7.5 mLSpectroelectrochemicalVessel MaterialPolytetrafluoroethyleneFTIR Compatibility Most, specify model and typeTemperature controlled crystal plates are available for thermalstudy of materials. <strong>PIKE</strong> <strong>Technologies</strong> offers temperature controllerswith digital and PC programmable set points.A T T E N U A T E D T O T A L R E F L E C T A N C E – L I Q U I D S , S O L I D S A N D I N - B E T W E E NTempPRO software for graphical setup and control of kinetic measurementsHeated crystalplates are availablefor the VeeMAX IIIfor TemperatureStudies25
P I K E T E C H N O L O G I E S W W W . P I K E T E C H . C O M 6 0 8 - 2 7 4 - 2 7 2 1VeeMAX III Base Optics (must select, insert spectrometer model for XX)P A R T N U M B E RD E S C R I P T I O N013-11XX VeeMAX III Variable Angle Specular Reflectance AccessoryNotes: VeeMAX III includes specular reflectance masks (2", 5/8" and 3/8"), purge tubes,purge kit and spectrometer base mount. Please see the FTIR instrument code sheet.VeeMAX III ATR Crystal Plates (must select 1 or more for ATR)P A R T N U M B E RD E S C R I P T I O N013-4021 Flat Plate, ZnSe, 45°013-4031 Flat Plate, ZnSe, 60°013-4041 Flat Plate, Ge, 45°013-4051 Flat Plate, Ge, 60°013-4061 Flat Plate, Ge, 65°013-4081 Flat Plate, Si, 45°013-4071 Flat Plate, Si, 60°013-4091 Flat Plate, ZnS, 45°013-4096 Flat Plate, ZnS, 60°013-3401 Liquids Retainer for VeeMAX III ATR crystals013-3501 VeeMAX III ATR Flow CellNotes: VeeMAX III Crystal Plates are pre-aligned and pinned-in-place. Changingcrystal plates is easy and fast to optimize sampling results. ZnS crystal plate isexcellent for deepest penetration of IR beam. Si crystal plate is excellent forFar IR ATR. If you need a crystal not listed here, please contact us. Reconditioningservice for used VeeMAX crystal plates is available.Heated VeeMAX III ATR Crystal Plates (optional)P A R T N U M B E RD E S C R I P T I O N013-4121 Heated Flat Plate, ZnSe, 45°013-4131 Heated Flat Plate, ZnSe, 60°013-4141 Heated Flat Plate, Ge, 45°013-4151 Heated Flat Plate, Ge, 60°013-4161 Heated Flat Plate, Ge, 65°013-4171 Heated Flat Plate, Si, 60°013-4181 Heated Flat Plate, Si, 45°013-4191 Heated Flat Plate, ZnS, 45°013-4196 Heated Flat Plate, ZnS, 60°076-1220 Digital Temperature Control Module076-1420 Digital Temperature Control Module, PC ControlNotes: Heated VeeMAX crystal plates may be heated to 130 °C. A temperaturecontroller must be selected.O R D E R I N G I N F O R M A T I O NVeeMAX III Pressure Clamp (must select for solids, films or powder analysis)P A R T N U M B E RD E S C R I P T I O N013-3101 VeeMAX III ATR Pressure Clamp025-3094 7.8 mm ATR Pressure TipNotes: Pressure clamp supplied with 20 mm tip for polymer films. The 7.8 mm pressuretip is required for monolayers on silicon or small samples. The pressure clamp isrequired for solids, films, coatings and powdered samples.VeeMAX III Sampling OptionsP A R T N U M B E RD E S C R I P T I O N013-2851 Motorized Option for VeeMAX III013-2801 Motorized Upgrade for VeeMAX III090-1000 Manual Polarizer, ZnSe090-1200 Manual Polarizer, KRS-5090-3000 Precision Manual Polarizer, ZnSe090-3200 Precision Manual Polarizer, KRS-5090-4000 Precision Automated Polarizer, ZnSe090-4200 Precision Automated Polarizer, KRS-5007-0300 <strong>PIKE</strong>Calc SoftwareNotes: <strong>PIKE</strong>Calc software provides easy calculations of depth of penetration, effectiveangle of incidence and critical angle for ATR measurements. Motorized Option includes<strong>PIKE</strong> <strong>Technologies</strong> AutoPRO software and controller. Other polarizer options arefound in the polarization section of this catalog. Motorized VeeMAX III andAutomated polarizer interface simultaneously with the same controller.Spectroelectrochemical ConfigurationP A R T N U M B E RD E S C R I P T I O N013-3300 Electrochemical Cell013-3110 ZnSe Crystal, 45°013-3130 ZnSe Crystal, 60°013-3112 Ge Crystal, 45°013-3132 Ge Crystal, 60°013-3114 Si Crystal, 45°013-3134 Si Crystal, 60°013-3115 ZnS Crystal, 45°013-3135 ZnS Crystal, 60°160-1144 CaF 2 Flat Window, 20 mm diameter160-1304 ZnSe Flat Window, 20 mm diameter013-3345 45° Crystal Holder013-3360 60° Crystal HolderNotes: The electrochemical configuration requires electrochemical cell and theVeeMAX III Specular Reflectance Accessory. Must select one or more crystals. Choose aCrystal Holder to match the crystal angle. A CaF 2 window may be used for specularreflectance sampling. Other window types for specular reflectance measurementsmay be found in our listing of transmission windows, 20 mm x 2 mm. Eitheralignment fixture is applicable for mounting a flat window. Electrodes supplied bythe end-user.Replacement PartsP A R T N U M B E R D E S C R I P T I O N013-4010 Mask Set for VeeMAX26
- Page 2 and 3: The PIKE Technologies team looksfor
- Page 4 and 5: TA B L E O F C O N T E N T SPages 1
- Page 6 and 7: Pages 81-114Transmission Sampling -
- Page 8 and 9: Sampling KitsIf you are not sure wh
- Page 10 and 11: Comprehensive Transmission Sampling
- Page 12 and 13: Valu-Line - High Performance Set of
- Page 14 and 15: Attenuated Total ReflectanceATR pro
- Page 16 and 17: MIRacle Crystal OptionsThe MIRacle
- Page 18 and 19: MIRacle Base Optics (must select, i
- Page 20 and 21: Selection of the digital control mo
- Page 22 and 23: G L A D IATR V I S I O N A C C E S
- Page 24 and 25: Multiple Reflection HATR -Maximum S
- Page 26 and 27: A large number of temperature-contr
- Page 28 and 29: ATRMax II Variable Angle Horizontal
- Page 30 and 31: ATRMax II System ConfigurationsPA R
- Page 34 and 35: JetStream ATR Accessory -Measuremen
- Page 36 and 37: ATR - Theory and ApplicationsAttenu
- Page 38 and 39: Porous Foam Sample with High Pressu
- Page 40 and 41: Diffuse ReflectanceDiffuse reflecta
- Page 42 and 43: DiffusIR -Research Grade Diffuse Re
- Page 44 and 45: UpIR -Upward Looking Diffuse Reflec
- Page 46 and 47: X, Y Autosampler - Transmission and
- Page 48 and 49: Diffuse Reflectance - Theory and Ap
- Page 50 and 51: Specular ReflectanceSpecular reflec
- Page 52 and 53: Changing the angle of incidence wit
- Page 54 and 55: 80Spec -Grazing Angle Specular Refl
- Page 56 and 57: 10Spec -Near-normal Sample Reflecti
- Page 58 and 59: Specular Reflectance - Theory and A
- Page 60 and 61: PolarizationPolarizers may be used
- Page 62 and 63: Infrared Polarizers - Theory and Ap
- Page 64 and 65: Integrating SpheresIntegrating sphe
- Page 66 and 67: A selection of Mercury cadmium tell
- Page 68 and 69: Quantitative measurement of active
- Page 70 and 71: A well-designed sphere has the samp
- Page 72 and 73: Remote SamplingAccessoriesHollow wa
- Page 74 and 75: F L E XIR A C C E S S O RY S P E C
- Page 76 and 77: Heated Liquid Sample Holder -Charac
- Page 78 and 79: MicrosamplingMicrosampling accessor
- Page 80 and 81: Switching from transmission to refl
- Page 82 and 83:
Compact Transmission/Reflection S84
- Page 84 and 85:
Micro Diamond Cell -For Compressing
- Page 86 and 87:
Beam CondensersP A R T N U M B E R0
- Page 88 and 89:
Transmission SamplingTransmission s
- Page 90 and 91:
RotatIR -Automated Rotating Sample
- Page 92 and 93:
X, Y Autosampler - Transmission and
- Page 94 and 95:
Demountable Liquid Cells -For Versa
- Page 96 and 97:
Long-Path Quartz Liquid Cells -For
- Page 98 and 99:
Demountable Liquid Cell Windows(mus
- Page 100 and 101:
Cryostat190 - Ultralow Temperature
- Page 102 and 103:
Bolt Press & Hydraulic Die - Low-Co
- Page 104 and 105:
Heated Platens Accessory - For Maki
- Page 106 and 107:
Auto-CrushIR -Programmable Hydrauli
- Page 108 and 109:
Sample Preparation Accessories -For
- Page 110 and 111:
Disks, Windows and Powders -For Tra
- Page 112 and 113:
Disks, 41 mm Diameter3 mm Thickness
- Page 114 and 115:
Short-Path Gas Cells -For Samples w
- Page 116 and 117:
Long-Path Gas Cells -For Measuremen
- Page 118 and 119:
Transmission Sampling Techniques -
- Page 120 and 121:
An alternate method for analysis of
- Page 122 and 123:
Special ApplicationsPIKE Technologi
- Page 124 and 125:
MappIR and MAP300 -For Automated An
- Page 126 and 127:
TGA/FTIR Accessory - Identification
- Page 128 and 129:
GC-FTIR Accessory -Combining GC Sep
- Page 130 and 131:
PA301 and PA101 - Photoacoustic Acc
- Page 132 and 133:
Semiconductor Applications - FTIR S
- Page 134 and 135:
UV-Vis AccessoriesThis is the most
- Page 136 and 137:
O R D E R I N G I N F O R M A T I O
- Page 138 and 139:
UV-Vis Spec -Slide Mounted Specular
- Page 140 and 141:
UV-Vis VeeMAX -Variable Angle Specu
- Page 142 and 143:
Peltier-Controlled Cuvette Holders
- Page 144 and 145:
Automated XY, R-Theta and Y-rotatio
- Page 146 and 147:
Standards, Softwareand DatabasesWe
- Page 148 and 149:
For diffuse reflectance measurement
- Page 150 and 151:
PIKECalc Software -For FTIR Samplin
- Page 152 and 153:
Transmission Spectral Databases -Hi
- Page 154 and 155:
HHand Press 95HATR 5, 17, 18, 19, 2
- Page 156 and 157:
Part Number Index007-0200 PIKE Temp
- Page 158 and 159:
026-2003 GladiATR Liquid Jacketed S
- Page 160 and 161:
121-1500 UV-Vis 15Spec 131121-2000
- Page 162 and 163:
160-5218 38 x 3 mm Polyethylene 104
- Page 164 and 165:
ORDERING TERMS,CONTACT INFORMATIONA
- Page 166 and 167:
FTIR INSTRUMENT CODEXXABB BomemFTLA