INSTALLATION INSTRUCTIONSFan Coils: FVM2X, FVM4XFigure 5A -Coil in Horizontal Left Application (FVM factory configuration)AFACTORY SHIPPEDHORIZONTAL LEFTAPPLICATIONBCCOILBRACKETCOILSUPPORTRAILDRAIN PANSUPPORTBRACKETCOILBRACKETHORIZONTALDRAIN PANAIR SEALASSEMBLYREFRIGERANTCONNECTIONSPRIMARY DRAINHORIZONTAL LEFTSECONDARY DRAINHORIZONTAL LEFTHorizontal Right Conversion of Units With SlopeCoils1. Remove blower <strong>and</strong> coil access panel <strong>and</strong> fittingpanel (refer to Figure 6).2. Remove coil mounting screw securing coilassembly to right side casing flange.3. Remove coil assembly.4. Lay fan coil unit on its right side <strong>and</strong> reinstall coilassembly with condensate pan down (refer toFigure 6).5. Attach coil to casing flange using coil mountingscrew previously removed.6. Make sure the pan cap in the fitting door is properlyseated on the fitting door to retain the low air leakrating of the unit.Figure 6Horizontal Right Conversion Applications - Slope CoilCOIL MOUNTINGSCREWBLOWERASSEMBLYSLOPE COILSKIDRAINPANREFRIGERANTCONNECTIONSPRIMARY DRAINSECONDARY DRAIN496 01 5001 02 Specifications are subject to change without notice5