OPERATING ENGINEZX<strong>27</strong>-31. Check that pilot control shut-off lever (1) is in the LOCKposition.2. Turn engine control lever (3) to around the middlebetween the slow and fast idle positions.3. Turn the key switch (2) to ON position. The preheatindicator (4) will light.4. Sound the horn to alert bystanders.5. As soon as preheat indicator (4) goes OFF, return keyswitch (2) to the START position to run the starter.IMPORTANT:Prevent starter damage and/or battery overdischarge. Never run the starter for morethan 10 seconds at a time. If the engine failsto start, return the key switch to OFF. Waitfor more than 30 seconds, then try again.6. Release key switch (2) immediately after the engine hasstarted. It will automatically return to the ON position.fNOTE:This machine is equipped with Auto Glow System.Sensing the coolant temperature, the duration ofpreheating is automatically set. Be sure to wait untilthe preheat indicator goes off with the key switchturned to the ON position, as specified above. Whenatmospheric temperature is low, it is possible tooperate the starter motor for within 15 seconds at atime.21M1NC-05-004M1M7-01-0073M1NC-00-0074M1NC-01-0223-4