CA Emergency Mgmt. Agency <strong>Safety</strong> <strong>Assessment</strong> <strong>Program</strong> <strong>Evaluator</strong> <strong>Manual</strong> April 2011Figure 2-40 – Plan Irregularities2.9.2 Evaluation CriteriaATC-20 has recommended criteria to assist evaluators on posting buildings. These conditionslisted below are also covered on the evaluation form. The SAP evaluator should look for theseconditions during the assessment. However, the evaluator must remember that these are verygeneral criteria and not hard-and-fast rules. One must use experienced judgment whendetermining how to post a building.Vertical Load System Columns noticeably out of plumb UNSAFE Buckled or failed columns UNSAFE Roof or floor framing separation from walls or other vertical supports UNSAFE Bearing wall, pilaster, or corbel cracking jeopardizing vertical support UNSAFE Other failure of vertical load carrying elements UNSAFELateral Force System Broken, leaning, or seriously degraded moment frames UNSAFE74