13.07.2015 Views

Design and Construction of Steel Plate Shear Walls - Eatherton ...

Design and Construction of Steel Plate Shear Walls - Eatherton ...

Design and Construction of Steel Plate Shear Walls - Eatherton ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

designed to resist the forces <strong>of</strong> the web plate, not onlydoes tension field action develop, but the tensiondiagonals can yield. Significant ductility <strong>and</strong> energyabsorption has been noted in this type <strong>of</strong> wall, that hasbeen referred to as “unstiffened” or “thin-walled”SPSW. It should be understood that the terms“stiffened” <strong>and</strong> “unstiffened” are a bit <strong>of</strong> a misnomer,however, as the essential difference in designmethodologies is the degree to which a plate is allowedto buckle, rather than whether stiffeners are used. Theweb plate <strong>of</strong> the SPSW shown in Fig 1 is designed todevelop tension field action at relatively low shear <strong>and</strong>would therefore be considered unstiffened. The 2005AISC Seismic provisions <strong>and</strong> the rest <strong>of</strong> this paperonly address unstiffened SPSW.In the 1990’s considerable research on SPSWwas done in the United States by pr<strong>of</strong>essors Bruneau,Berman, Elgaaly, Caccese, Astaneh, <strong>and</strong> others. U.S.design provisions were, for the first time, published inthe 2005 AISC Seismic provisions. Additionally,Bruneau <strong>and</strong> Sabelli are producing an AISC designguide on SPSW which is expected to includerecommendations for seismic <strong>and</strong> non-seismicapplications for SPSW. With these upcomingpublications, SPSW will gain a new level <strong>of</strong> exposurewith U.S. engineers. This paper is geared towardsdesign engineers who might be considering usingSPSW <strong>and</strong> contains:1. Discussion <strong>of</strong> design considerations whenusing the 2005 AISC Seismic Provisions.2. Comparison <strong>of</strong> SPSW to special concentrically braced frames <strong>and</strong> special momentframes.3. Summary <strong>of</strong> reasons why the author used SPSW for 3 large residences in NorthernCalifornia <strong>and</strong> experiences encountered in their design <strong>and</strong> construction.4. Suggestions for design <strong>of</strong> SPSW <strong>and</strong> future editions <strong>of</strong> SPSW code provisions.<strong>Design</strong> Considerations for SPSWFigure 1 – <strong>Steel</strong> plate shear wall usedin a high-end residence in San MateoCounty, CA.The 2005 AISC Seismic Provisions refer to SPSW as special plate shear walls. The termspecial indicates that, like special concentrically braced frames or special moment frames, thatspecial plate shear walls are expected to have increased ductility over their ordinarycounterparts. While the AISC Seismic Provisions do not include ordinary steel plate shear walls,if they are included in future editions it can be conjectured that one <strong>of</strong> the differences may besimple shear beam-to-column connections (as opposed to moment connections required forSPSW).In the process <strong>of</strong> SPSW design, the author has come across several issues that require

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!