Manuale Officina LGW 523-627 - lombardini service
Manuale Officina LGW 523-627 - lombardini service
Manuale Officina LGW 523-627 - lombardini service
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Electric System9Temperature sensor for control unitIn engines fitted with the above-mentioned type of control unit, theintroduction of the glow plugs depends on a temperature sensor thatvaries preheating temperature in relation to the coolant temperature.Characteristics:Temperature range ............... -30 ÷ +50°CVoltage range........................ 6÷24 VTemperature max. ................ 150°CMax. tightening torque. ......... 30 Nm.213214215216Oil pressure switch (Fig. 215)Characteristics:Opening pressure: 0,15÷0,45 bar (for gen-sets: 1,4 bar). Tightening torque 25 Nm.Coolant high temperature lamp sensor (Fig. 216)Characteristics:Circuit ............................................. single poleVoltage range................................. 6÷24 VMax. Power Absorption.................. 3 WClosing temperature ...................... 107÷113°C Tightening torque 25 Nm.FOCS Workshop Manual_cod. 1.5302.351_7° ed_ rev. 06- 93 -