11. Operation Control11.1 Basic FunctionInverter control, which equipped with a microcomputer in determining the most suitable operation mode as timepasses, automatically adjusts output power for maximum comfort always. In order to achieve the suitable operationmode, the microcomputer maintains the set temperature by measuring the temperature of the environment andperforming temperature shifting. The compressor at outdoor unit is operating following the frequency instructed bythe microcomputer at indoor unit that judging the condition according to internal setting temperature and intake airtemperature.11.1.1 Internal Setting TemperatureOnce the operation starts, remote control setting temperature will be taken as base value for temperature shiftingprocesses. These shifting processes are depending on the air conditioner settings and the operation environment.The final shifted value will be used as internal setting temperature and it is updated continuously whenever theelectrical power is supplied to the unit.Remote Control Setting Temperature16°C ~ 30°C<strong>Indoor</strong> Air Temperature Shifting<strong>Outdoor</strong> Air Temperature ShiftingSetting Temperature Limit Checking(Min: 16°C; Max: 33°C)Internal Setting Temperature11.1.2 Cooling Operation11.1.2.1 Thermostat control• Compressor is OFF when intake Air Temperature - Internal Setting Temperature < -0.5°C.• Compressor is ON after waiting for 3 minutes, if the Intake Temperature - Internal Setting Temperature >Compressor OFF point.11.1.3 Soft Dry Operation11.1.3.1 Thermostat control• Compressor is OFF when Intake Temperature - Internal Setting Temperature < -1.0°C.• Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setting Temperature >Compressor OFF point.11.1.3.2 Automatic Operation• This mode can be set using remote control and the operation is decided by indoor intake air temperature.• During operation mode judgment at the beginning of the Auto Mode operation, indoor fan motor (with speed ofLo-) is running for 30 seconds to detect the indoor intake air temperature.• The operation mode is decided based on below chart.23°CCoolingoperationSoft Dryoperation<strong>Indoor</strong> intakeAir Temp• After the operation mode is decided, the unit operation will follow the respective operation mode control.47

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!