13.07.2015 Views

Indoor Unit Outdoor Unit CS-PS9NKV CS-PS12NKV CS ... - Panasonic

Indoor Unit Outdoor Unit CS-PS9NKV CS-PS12NKV CS ... - Panasonic

Indoor Unit Outdoor Unit CS-PS9NKV CS-PS12NKV CS ... - Panasonic

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

16.1.2 <strong>CS</strong>-<strong>PS12NKV</strong> CU-<strong>PS12NKV</strong>• Cooling Characteristico Room temperature: 27°C (DBT), 19°C (WBT)o Operation condition: High fan speedo Piping length: 7.5mo Compressor Frequency = Fc16.90022016.400Outlet AirTempeature (°C)15.90015.40014.90030 31 32 33 34 35 36 37 38 39 40 41 42 43<strong>Outdoor</strong> Air Temperature (°C)CoolingCapacity (kW)3.3003.2003.1003.0002.9002.8002.7002.60030 31 32 33 34 35 36 37 38 39 40 41 42 43<strong>Outdoor</strong> Air Temperature (°C)4.7004.500Current(A)4.3004.1003.9003.70030 31 32 33 34 35 36 37 38 39 40 41 42 43<strong>Outdoor</strong> Air Temperature (°C)1.1101.100Gas Side PipingPressure (MPa)1.0901.0801.0701.06030 31 32 33 34 35 36 37 38 39 40 41 42 43<strong>Outdoor</strong> Air Temperature (°C)91