14.3 Error Code TableDiagnosisEmergencyAbnormality / Protection control Abnormality JudgmentdisplayOperationPrimary location to verifyH00 No abnormality detected - Normal operationH11 <strong>Indoor</strong> / <strong>Outdoor</strong> abnormalcommunication> 1 min after startingoperation<strong>Indoor</strong> fan operationonly• Internal / external cable connection• <strong>Indoor</strong> / outdoor PCBH12 Connection capability rank abnormality Continuously for 90 sec- -after power suppliedH14 <strong>Indoor</strong> intake air temperature sensorabnormalityContinue for 5 sec. - • Intake air temperature sensor(defective or disconnected)H15 <strong>Outdoor</strong> compressor temperature sensorabnormalityContinue for 5 sec. - • Compressor temperature sensor(defective or disconnected)H16 <strong>Outdoor</strong> current transformer open circuit - - • <strong>Outdoor</strong> PCB• IPM (Power transistor) moduleH19 <strong>Indoor</strong> fan motor mechanism locked 7 occurrencescontinuously- • <strong>Indoor</strong> PCB• Fan motorH23 <strong>Indoor</strong> heat exchanger temperaturesensor abnormalityContinue for 5 sec. ○ • Heat exchanger temperature sensor(defective or disconnected)H27 <strong>Outdoor</strong> air temperature sensorabnormalityContinue for 5 sec. ○ • <strong>Outdoor</strong> temperature sensor(defective or disconnected)H28 <strong>Outdoor</strong> heat exchanger temperaturesensor abnormalityContinue for 5 sec. ○ • <strong>Outdoor</strong> heat exchangertemperature sensor (defective ordisconnected)H30 <strong>Outdoor</strong> discharge pipe temperaturesensor abnormalityContinue for 5 sec. ○ • <strong>Outdoor</strong> discharge pipe temperaturesensor (defective or disconnected)H33 <strong>Indoor</strong> / outdoor wrong connection - - • <strong>Indoor</strong> / outdoor supply voltageH38 <strong>Indoor</strong> / outdoor mismatch (brand code) - - -H97 <strong>Outdoor</strong> fan motor mechanism locked 2 occurrences within 30minutes- • <strong>Outdoor</strong> PCB• <strong>Outdoor</strong> Fan MotorH98 <strong>Indoor</strong> temperature rise abnormality - - • Air filter dirty• Air circulation short circuitH99 <strong>Indoor</strong> heat exchanger freeze prevention- - • Insufficient refrigerantprotection• Air filter dirtyF11 4 way valve switching failure * 4 occurrences within 30- • 4-way valveminutes• v-coilF90 System and compressor microcomputer 2 occurrences within 5- • Compressorcommunication error(for S10*** only)seconds• <strong>Outdoor</strong> PCBF90 Power factor correction abnormality 4 occurrences within 20- • <strong>Outdoor</strong> PCBminutesF91 Refrigerant cycle abnormal 2 occurrences within 20minutes- • No refrigerant ( 3-way valve isclosed)F93 <strong>Outdoor</strong> compressor abnormal revolution 4 occurrences within 20- • <strong>Outdoor</strong> compressorminutesF95 Cooling high pressure protection 4 occurrences within 20- • <strong>Outdoor</strong> refrigerant circuitF96Intelligent power transistor overheatingprotectionminutesF97 Compressor temperature rise protectioncontrolF98 Total running current protection 3 times occurrence withinF99<strong>Outdoor</strong> direct current (DC) peakdetection- • Excess refrigerant• Improper heat radiation• IPM (Power transistor)4 times occurrence within- • Insufficient refrigerant20 minutes• Compressor- • Excess refrigerant20 minutes• Improper heat radiation7 times occurrencecontinuously- • <strong>Outdoor</strong> PCB• IPM (Power transistor)• CompressorNote:“○” – Frequency measured and fan speed fixed“ * ”– For cooling only model, it is the indication when indoor heat exchanger sensor or indoor air intake sensor hasabnormality.The memory data of error code is erased when the power supply is cut off, or press the Auto Switch until “beep”sound heard following by pressing the CHECK button at remote control.Although operation forced to stop when abnormality detected, emergency operation is possible for certain errors(refer to Error Code Table) by using remote control or Auto OFF/ON button at indoor unit. However, the remotecontrol signal receiving sound is changed from one “beep” to four “beep” sounds.59

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!