11.2 <strong>Indoor</strong> Fan Motor Operation11.2.1 Basic Rotation Speed• Manual Fan Speedo Fan motor’s number of rotation is determined according to remote control setting.Remote control ○ ○ ○ ○ ○Tab Hi Me+ Me Me- Lo• Auto Fan Speedo According to room temperature and setting temperature, indoor fan speed is determined automatically.o The indoor fan will operate according to pattern below.Fan Speed a b c d e f g h a bHigherMediumLower[1 pattern : 10s]• Feedback controlo Immediately after the fan motor is started, feedback control is performed once every second.o During fan motor on, if fan motor feedback ≥ 2550 rpm or