13.07.2015 Views

309244D 50:1 Ratio Double Acting Falcon Grease Pumps - Graco Inc.

309244D 50:1 Ratio Double Acting Falcon Grease Pumps - Graco Inc.

309244D 50:1 Ratio Double Acting Falcon Grease Pumps - Graco Inc.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Performance Charts<strong>50</strong>:1 <strong>Falcon</strong> <strong>Grease</strong> <strong>Pumps</strong> Fluid Outlet PressureTest Fluid: No. 2 grease (specific gravity: 0.92)(56, 560)Cycles Per Minute*21 42 6384 105 115FLUID OUTLET PRESSURE –– psi (MPa, bar)(49, 490)(42, 420)(35, 3<strong>50</strong>)(28, 280)(21, 210)(14, 140)(7, 70)ABCD 2.2(0.18) (0.36) (0.54) (0.73)(0.91) (1.0)DELIVERY –– lb/min (kg/min)To find Fluid Outlet Pressure (psi/MPa/bar) at aspecific delivery rate (lb/min or kg/min) and operatingair pressure (psi/MPa/bar):1. Locate delivery rate along bottom of chart.2. Follow vertical line up to intersection with selectedfluid outlet pressure curve.3. Follow left to scale to read fluid outlet pressure.*Recommended pump speed for continuous operation: 95 cpmMaximum recommended pump speed: 115 cpmABCDFluid Pressure Curvesat 1<strong>50</strong> psi (0.9 MPa, 10 bar) air pressureat 100 psi (0.7 MPa, 7 bar) air pressureat 70 psi (0.48 MPa, 4.8 bar) air pressureat 40 psi (0.28 MPa, 2.8 bar) air pressure