13.07.2015 Views

Manual Install Slimline P374-1900 Rev. 1

Manual Install Slimline P374-1900 Rev. 1

Manual Install Slimline P374-1900 Rev. 1

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SECTION 8TroubleShootingTOTALINESYMPTOM: The air conditioning does not attempt toturn on.CAUSE: The compressor timer lockout may prevent theair conditioner from turning on for a period of time.REMEDY: Consult the Owner's <strong>Manual</strong> in the Setupsection to defeat the cycles per hour andcompressor timeguard.8SYMPTOM: The display is blank.CAUSE: Lack of proper power.REMEDY: Make sure power is turned on to the furnaceand that you have 24vac between R & W. If C isused, 24vac between R & C.SYMPTOM: The air conditioning does not attempt toturn on.CAUSE: The cooling setpoint is set too high.REMEDY: Consult the Owner's <strong>Manual</strong> in the Setupsection to lower the cooling setpoint limit.SYMPTOM: The heating does not attempt to turn on.CAUSE: The heating setpoint is set too low.REMEDY: Consult the Owner's <strong>Manual</strong> in the Setupsection to raise the heating setpoint limit.Page 8.1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!