<strong>SIMOVERT</strong> <strong>MASTERDRIVES</strong> <strong>Vector</strong> <strong>Control</strong>Engineering InformationMulti-motor drivesCompact and chassis unitsCabinet unitsRectifier/regenerative units (continued)The rectifier/regenerativeunits require a relative impedancevoltage of at least5 % on the supply side. Thisis achieved by usinga4%line commutating reactor oran appropriate convertertransformer. The rectifier/regenerative units are decoupledfrom the supply andsystem perturbations arelimited in accordance withDIN VDE 0160.The maximum relativeimpedance voltage mustnot, however, exceed 10 %.In practice, the followingcombinations can beexpected.Supply(transformer)Linereactorv D 3% 4% 2%3%