13.07.2015 Views

SIMOVERT MASTERDRIVES Vector Control - Industry

SIMOVERT MASTERDRIVES Vector Control - Industry

SIMOVERT MASTERDRIVES Vector Control - Industry

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Compact PLUS/compact andchassis units · cabinet units<strong>SIMOVERT</strong> <strong>MASTERDRIVES</strong> <strong>Vector</strong> <strong>Control</strong>Engineering InformationCommunicationPROFIBUS DPIf the PROFIBUS DP is used,the CBP or CBP2 communicationboard is necessary forinterfacing drives to higherlevelautomation systems.With extended functionality,CBP2 is fully compatiblewith CBP and has replaced itas standard. In the following,therefore, “CBP”signifiesboth boards; individual specialfeatures of CBP2 are indicated.Functionality of the CBP Cyclical user data exchangewith the master accordingto the “PROFIBUS Profilefor PROFIDRIVE Variable-Speed Drives ”(Order No.3.071, PROFIBUS Nutzerorganisatione.V., Karlsruhe). Acyclical communicationchannel for exchangingparameter values up to alength of 118 words with aSIMATIC S7 CPU. Acyclical communicationchannel for connectingthe Drive ES Basic start-up,parameterization anddiagnostics tools. Support of the PROFIBUScontrol commands, SYNCand FREEZE, for synchronizeddata transfer from themaster to several slavesand vice versa.Extended functionalityof CBP2to PROFIBUS profile, drivesystems V3 PROFIDRIVE Flexible configuration ofcyclic messages at up to16 process data words Direct communication fordirect exchange of data betweenslaves Acyclic communicationchannel for direct access ofa SIMATIC OP to a drive.System connectorFixing screwFig. 6/62CBP communication boardPossible user data structures with CBP and CBP2DA65-5102Fixing screwLED (green)LED (yellow)LED (red)9-pole Sub D terminalX448PPO-Type PKW area PZD area FunctionalityPKW IND PWE PZD1 PZD16 CBP CBP2PPO1 fixed length: 4 words fixed length: 2 words ✔ ✔PPO2 fixed length: 4 words fixed length: 6 words ✔ ✔PPO3 fixed length: 0 words fixed length: 2 words ✔ ✔PPO4 fixed length: 0 words fixed length: 6 words ✔ ✔PPO5 fixed length: 4 words fixed length: 10 words ✔ ✔none 0 or 4 words flexible configurable from1 to 16 words✔PKW: Parameter ID value IND: IndexPZD: Process dataPWE: Parameter valuePKE: Parameter IDCyclic exchange ofuser dataIn the PROFIBUS profile onwhich the CBP functionalityis based, the structure of theuser data, amongst otheritems, with which a DP mastercan access the drives isdefined. There are five permanentlydefined PPO (parameterprocess-data objects);these are subdividedinto a PKW area (parameteridentifier value area, up to4 words) and the PZD area(process data area, up to10 words).The PKW area enables readingand writing of parametervalues and the reading ofparameter descriptions. Thismechanism is used to visualizeor change any of theslaves’parameters.The PZD area contains thedata – such as control wordsand setpoints needed forprocess control – from theautomation system to thedrive or status words and actualvalues from the drive tothe automation system.When a CBP2 is used, localuser data structures with upto 16 process data words cannow also be utilized in additionto the five PPO types.Technical data of the CBP RS485 interface acc. toEN 50 170, short-circuitproof and floating Baud rates from 9.6 Kbit/sto 12 Mbit/s.Mounting of the CBPIn <strong>MASTERDRIVES</strong> <strong>Vector</strong><strong>Control</strong>, slots A, C, Eand G in the electronicsbox are available (see alsopage 6/54). For slots Gand E, the local bus adapter(6SE7090–0XX84–4HA0)and the adapter board(6SE7090–0XX84–0KA0)are necessary.6Siemens DA 65.10 · 2003/20046/57

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!