13.07.2015 Views

SIMOVERT MASTERDRIVES Vector Control - Industry

SIMOVERT MASTERDRIVES Vector Control - Industry

SIMOVERT MASTERDRIVES Vector Control - Industry

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>SIMOVERT</strong> <strong>MASTERDRIVES</strong> <strong>Vector</strong> <strong>Control</strong>Engineering InformationTechnologyCompact and chassis unitsCabinet units6Technology applications with the T300The T300 can be used to provideadditional technologicalfunctions for compact andchassis units (e.g. for closedlooptension and positioncontrol, coilers, winders,closed-loop synchronousand positioning controls,transverse cutters, hoistingequipment and drive-relatedcontrol functions).Supplementary technologicalfunctions which are oftenrequested are offered asstandard software packageson pre-programmed memorymodules.The T300 and SIMADYN Dare fully compatible witheach other.Users who wish to createspecial applications or whowish to market their owntechnological know-how cancreate their own technologicaldesign on the T300 byusing the graphics-orientedSTRUC planning languageknown from the SIMADYN Dsystem (See also orderingdata in Section 3).Fig. 6/78 shows the most importanthardware functionsof the T300.The technological functionsare configured with STRUCand cyclically executed bythe processor. The closedloopcontrol sampling timeis a minimum of 1 ms (seeCatalog ST DA).An overview of the hardwareand software componentsof the T300 is provided inFig. 6/79.An almost delay-free parallelinterface (dual-port RAM)permits data transfer betweenthe basic unit andthe T300.The serial connections canbe directly connected to terminalson the T300. All otherexternal signals can be connectedat the SE300 terminalblock outside the base unit.15V/100mAforsupplyingpulses is available at SE300(see Fig. 6/78).An external 24 V DC powersupply must be provided ifbinary inputs and outputshave to be controlled. Thebase unit can also providethis voltage supply as long asthe total current at terminalsX101.13, 23 of the base unitis < 150 mA.The software package isparameterized – irrespectiveof which software package isused – with the help of thefollowing: a Drive ES or DriveMonitorPC (for a description seepages 2/10 to 2/15) the PMU operator controland parameterizing unit the OP1S user-friendlycontrol unit an interface board (CBP,SCB1, SCB2) via an interface of the T300with the service start-upprogram (see selectiontable on page 3/88).Altered parameters can bestored in the EEPROM(non-volatile).Fig. 6/77T300 board with memory module6/72Siemens DA 65.10 · 2003/2004

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!