RotoFlex Motor or Compressor motor will not run.RTX 750 and RTX 1000See pages 00, for the steps.See step 1.Do you haveover 100 AC volts?NORepair orreplace thepower Cord.YESSee step 2. Do you haveover 100 AC volts?NORepair orreplace Whitewire or wire splice.YESSee step 3.Do you haveover 100 AC volts?YESNORepair orreplace Black wirefrom power cord topower switch.See step 4.Do you haveover 100 AC volts?NOReplace thepower switch.YESSee step 5. Do you haveover 100 AC volts?NORepair orreplace Blackwire or wire splice.12