RotoFlex Motor motor will not run.RTX 750 and RTX 1000Does theAir Compressormotor run?YESSee step 1.Do you haveover 100 AC volts?YESSee step 2.Do you haveover 100 AC volts?NO See Motorswill not run.NONORepair orreplace Whitewire or wire splice.Repair orreplace Blackwire or wire splice.110-120 ACV-POWERSWITCH-BLACKStep 1Power switch ON.Cord plugged in.Wires connectedto selector switch.Selector switch ON.Meter on AC VoltsSELECTORSWITCHBLUE110-120 ACV-Step 2Power switch ON.Cord plugged in.Wires connectedto selector switch.Selector switch ON.Meter on AC VoltsYESSee Capacitortest. Does theCapacitor test ok?YESNOReplace theCapacitor.To MotorYellowWHITE+WHITEGREENPOWERCORDPOWERSWITCHBLACKSELECTORSWITCH-BLUEReplace theRotoflex Motor.BLACKCAPACITORBLACKBLACKTo MotorYellowWHITE+GREENPOWERCORDMOTORWHITEPOWERSWITCHSELECTORSWITCHBLUEGREENGROUNDYELLOWGREENBLACKBLUEGREENWHITEPOWERCORDBLACKWHITEAIR COMPRESSORBLACKBLACK14