13.07.2015 Views

Official Proceedings - AIUM

Official Proceedings - AIUM

Official Proceedings - AIUM

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

American Institute of Ultrasound in Medicine <strong>Proceedings</strong> J Ultrasound Med 32(suppl):S1–S134, 2013urements using an Auto Mod-MPI system as a novel technique for measuringthe Mod-MPI.Methods—This was a prospective study of 117 cases from 110normal singleton fetuses at 16.4 to 35.0 weeks of gestation. Two experiencedoperators each measured the left Mod-MPI twice manually and twiceautomatically using the Auto Mod-MPI system (Samsung Electronics Co,Ltd). This system operates as follows. At first, the clear image of the openingand closing clicks of mitral and aortic valves should be obtained. Whenthe operator places the cursor on the aortic outflow in a single Dopplerwaveform and presses the Set key, the system automatically places thecalipers at the beginning of each click and calculates the Mod-MPI within0.1 second. We evaluated whether the automated system can successfullymeasure the left Mod-MPI. Intraoperator and interoperator reproducibilitywere also assessed using intraclass correlation coefficients (ICCs), and themanual and automated measurements obtained by a more experienced operatorwere compared using the Bland-Altman plot and ICCs.Results—Among 117 cases, both operators successfully measuredthe left Mod-MPI in 114 cases using the Auto Mod-MPI system (successrate, 97.4%). All values of automated measurements by both operatorswere perfectly matched (ICC = 1 for both intraoperator and interoperatorreproducibility). Among the manual measurements, the intraoperator ICCsof both operators were 0.910 (95% confidence interval [CI], 0.872–0.937)and 0.826 (95% CI, 0.758–0.877), respectively. The interoperator ICCwas 0.731 (95% CI, 0.678–0.785), and the mean difference between theoperators was 0.017 (95% CI, 0.010–0.024). There was good agreementbetween the manual and automated values measured by the more experiencedoperator (ICC = 0.841).Conclusions—The Auto Mod-MPI system is a fast and reliabletechnique for measuring the Mod-MPI with excellent reproducibility.1541081 First-Trimester Pregnancy Dating by Fetal Heart Rate:A Simple FormulaSarah Obican, 1,2 * Slava Khodak Gelman, 2 John Larsen 21Maternal-Fetal Medicine, Obstetrics and Gynecology,Columbia University, New York, New York USA; 2 Obstetricsand Gynecology, Maternal-Fetal Medicine, George WashingtonUniversity, Washington, DC USAObjectives—Accurate dating is an essential tool in the managementof pregnancies. Thus, we sought:(1) to develop a new formula that establishes an association betweenfetal heart rate (FHR) and gestational age in pregnancies

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!