American Institute of Ultrasound in Medicine <strong>Proceedings</strong> J Ultrasound Med 32(suppl):S1–S134, 2013pass filter (HPF) with an adjustable cutoff frequency, and differentiationof the displacement vs time data. The latter determines the axial velocityof the propagating pulse and allows the wave arrival time to be determinedfrom the peak slope of the leading edge. This differentiation acts as a rampfilter in the frequency domain to reduce the effects of low-frequency motion.After filtering, SWSs were estimated using the arrival time as a functionof position data and the radon sum algorithm.Results—Results obtained to date indicate that the applicationof motion filters does affect the reconstructed SWS. Both the HPF anddifferentiation filter bias the estimated group velocity to the higher phasevelocity components; this effect is less significant for the quadratic filter.The differentiation filter leads to an ≈16% increase in SWS estimates overthe range of 1.5 to 4.0 m/s compared to the quadratic filter. For the HPF,increasing the cutoff frequency from 25 to 150 Hz increases the SWS≈13% over the same SWS range.Conclusions—Preprocessing algorithms used to remove lowfrequencynoise and motion artifacts from in vivo data can skew groupvelocity SWS estimates toward the higher phase velocity components.1540991 Evaluation of Shear Wave Elasticity Imaging for Characterizingthe Contribution of Coronary Perfusion to CardiacDiastolic StiffnessMaryam Vejdani-Jahromi,* Annette Kiplagat, YoungJoong-Kim, Douglas Dumont, Gregg Trahey, Patrick WolfBiomedical Engineering, Duke University, Durham, NorthCarolina USAObjectives—Heart failure is one of the leading causes of deathin the world in which mechanical properties of the cardiac tissue are damaged.Diastolic heart failure occurs when the left ventricle loses its complianceto receive a sufficient volume of blood. Currently, there is nouniversally accepted technique to evaluate changes in mechanical propertiesof cardiac tissue. Shear wave elasticity imaging (SWEI) is an ultrasound-basedtechnique used to evaluate the stiffness of the tissue bymeasuring the shear wave speed of propagation. To evaluate the capabilityof SWEI in determining the contribution of coronary perfusion to diastolicstiffness, normal and hypoperfused rabbit hearts were studied.Methods—Six rabbit hearts were isolated on a Langendorffpreparation, perfused with Tyrode solution. Data were acquired using aVF10-5 linear transducer on a Sonoline Antares ultrasound system (SiemensMedical Solutions, Mountain View, CA) with a focal point of 1.6 cm, transmitfrequency of 5.7 MHz and F-number of 1.5. The probe was fixed approximately1 cm from the left ventricular free wall along the short axis andacquired data from the same location. Hypoperfusion was done in 3 isolatedhearts by reducing the perfusion pressure until the flow rate was half of normal,and SWEI data were recorded before and 10 minutes after. Three rabbithearts with a normal flow rate were studied as control subjects.Results—Initial results showed that reduction of 50% in perfusionpressure caused an average decrease of 27.7% in the shear wave velocityand 47.7% in the shear modulus, while normal hearts showedincreases of 9.0% and 18.7% for the shear wave velocity and shear modulus,respectively.Conclusions—From these preliminary data, we conclude thatthe shear wave velocity and shear modulus recorded by SWEI can showthe contribution of coronary perfusion pressure to diastolic stiffness. Thisnew ultrasound-based imaging modality can be used to assess, characterize,and quantify the mechanical properties of the heart.Table 1Hearts Shear Wave Velocity, m/s Shear Modulus, kPaHypoperfused before 1.69 2.84Hypoperfused after 1.22 1.49Normal before 1.23 1.50Normal after 1.34 1.79S111540671 Feasibility and Reproducibility of Right Ventricular StrainMeasurement by Speckle-Tracking Echocardiography inPreterm InfantsPhilip Levy, 1 * Gautam Singh, 1 Tim Sekarski, 1 Aaron Hamvas, 1Mark Holland 1,2 1 Pediatrics, Washington University Schoolof Medicine, St Louis, Missouri USA; 2 Physics, WashingtonUniversity, St Louis, Missouri USAObjectives—The right ventricle (RV) is the dominant ventriclein premature and term neonates, and its function is an important determinantof the clinical status and prognosis of congenital and acquired cardiopulmonarypathologies. Myocardial strain and the strain rate represent2 sensitive measures of cardiac function. 2D speckle-tracking echocardiography(2DSE) is an angle-independent method for strain measurementbut has not been applied in preterm infants for assessment of RVfunction. The aim of this study was to evaluate the feasibility and reproducibilityof 2DSE-measured RV global longitudinal strain in preterm infantsand establish standardized methods for acquiring and analyzing strainmeasurements.Methods—2DSE (GE EchoPac) was used to measure the peakglobal longitudinal strain (pGLS) and strain rate (pGLSR) in the apical 4-chamber view of the RV in 50 preterm infants (27 ± 1 weeks at birth) at32 weeks postmenstrual age. Images were acquired with frame rates between60 and 100 Hz for 3 cardiac cycles and stored for offline analysis.Two observers measured the RV pGLS and pGLSR in 25 randomly selectedimages. Interobserver and Intraobserver reproducibility were assessedusing Bland-Altman analysis (relative bias, 95% limits ofagreement [LOA]), and the correlation was tested using linear regression.Results—Strain imaging was feasible from 85% of the acquisitions.Intraobserver 2DSE RV pGLS and pGLSR reliability demonstratedhigh reproducibility (bias, 4%; 95% LOA, –2.1 to +1.9; r = 0.98;P < .01; and bias, 6%; 95% LOA, –0.29 to +0.26; r = 0.94; P < .01, respectively).Interobserver 2DSE RV pGLS and pGLSR reliability alsoshowed high reproducibility (bias, 7%; 95% LOA, –4.1 to +3.9; r = 0.92;P < .01; and bias, 7%; 95% LOA, –0.41 to +0.42; r = 0.94; P < .01, respectively).Conclusions—Our study demonstrates high feasibility and reproducibilityof RV strain measurements by 2DSE in preterm infants andoffers specific recommendations for image acquisition and data analysisthat reduce measurement variability. Strain measurement by 2DSE offersa robust tool for the assessment of global RV function that is not achievedby conventional methods. (Supported by National Institutes of Healthgrants 1U01 HL101465 and R21 HL106417.)1541514 Statistical Comparison of Backscatter Coefficients for MATand 4T1 Tumors Across Multiple Ultrasound-Imaging SystemsDouglas Simpson, 1 * Nathaniel Hirtz, 1,2 William O’Brien Jr 21Statistics, 2 Bioacoustics Research Laboratory, Electrical andComputer Engineering, University of Illinois at Urbana-Champaign,Urbana, Illinois USAObjectives—Quantitative ultrasound measurements such as thebackscatter coefficient (BSC) have the potential to greatly enhance tissuecharacterization and identification of tumors. A balanced experiment wasconducted to compare consistency across transducers and efficacy for distinguishing2 well-characterized animal tumor types.Methods—The study included induced 4T1 and MAT tumorsin mice and rats. Animals were scanned with 5 different transducers witha target of 5 scan lines per tumor region of interest. BSCs were computedfor each scan. The resulting BSC data were analyzed across tumor typesand transducers using spatially dependent linear mixed model analysis,where the spatial dependence was between neighboring frequencies withinthe same scan line. The model allowed comparison of BSC curves fromtransducers with varying frequency ranges.Results—For 4T1 tumors, transducer differences were not statisticallysignificant. For MAT tumors, significant differences between

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!