13.07.2015 Views

320386-001 - AO Smith Water Heaters

320386-001 - AO Smith Water Heaters

320386-001 - AO Smith Water Heaters

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

GABLE VENTTO OUTDOORSINSTALL ABOVEINSULATIONALTERNATIVEOPENINGLOCATIONCONFINEDSPACEOUTLETAIR TOATTIC 1 SQ.INCH PER4000 BTUHCONFINEDSPACE1 SQ. INCHPER 3000 BTUHALTERNATEAIR INLETINLET AIR FROMTHE CRAWL SPACEALL AIR FROM OUTDOORS - USING A SINGLE PERMANENT OPENING1 SQ. INCH PER4000 BTUHOPENFOUNDATIONVENTALL AIR FROM OUTDOORS: INLET AIR FROM VENTILATEDCRAWL SPACE/OUTLET AIR TO VENTILATED ATTICCONFINEDSPACEFIGURE 6.GABLE VENTTO OUTDOORSINSTALL ABOVEINSULATIONOUTLET AIRTO ATTIC1 SQ. INCHPER 4000BTUHINLET AIR DUCT1 SQ. INCH PER4000 BTUH12” MAXIMUMALL AIR FROM OUTDOORS THROUGH VENTILATED ATTICCONFINEDSPACEFIGURE 7.1 SQ. INCH PER2000 BTUHOUTLETOUTDOORAIR DUCTSVent Pipe SystemFIGURE 8B.This water heater uses a non-direct, single-pipe ventsystem to remove exhaust gases created by the burning offossil fuels. Air for combustion is taken from the immediatewater heater location or is ducted in from the outside (see“Combustion Air and Ventilation”).This water heater must be properly vented for the removalof exhaust gases to the outside atmosphere. Correctinstallation of the vent pipe system is mandatory for theproper and efficient operation of this water heater and isan important factor in the life of the unit.The vent pipe must be installed according to all local andstate codes or, in the absence of local and state codes, the“National Fuel Gas Code”, ANSI Z223.1(NFPA 54)-currentedition. The vent pipe installation must not be obstructedso as to prevent the removal of exhaust gases to theoutside atmosphere.IMPORTANT: The use of vent dampers is notrecommended by the manufacturer of this water heater.Although some vent dampers are certified by CSAInternational, this certification applies to the vent damperdevice only and does not mean they are certified for useon this water heater.U.L. recognized fuel gas and carbon monoxide (CO)detectors are recommended in all applications and shouldbe installed using the manufacturer’s instructions and localcodes, rules, or regulations.IMPORTANT: If you lack the necessary skills requiredto properly install this venting system, you should notproceed, but get help from a qualified technician.Draft Hood InstallationSHEET METAL SCREWS (FOUR PROVIDED)INLETLEGSDRAFT HOODLEGS1 SQ. INCH PER2000 BTUHALL AIR FROM OUTDOORS USING HORIZONTAL DUCTSSLOTJACKET TOPINSTALL THE DRAFT HOOD WITHTHE FOUR SCREWS PROVIDED.SLOTFIGURE 8A.13FIGURE 9

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!