Appendix C. Recommended Water Quality Monitoring Program<br />

The existing water quality monitoring program provides an excellent foundation <strong>for</strong> tracking<br />

baseline water quality conditions. We recommend certain modifications, as outlined below.<br />

Program<br />

element<br />

Parameters<br />

measured<br />

<strong>Ponds</strong><br />

monitored<br />

by <strong>Town</strong><br />

Current Program Recommended Program Rationale<br />

Secchi disk<br />

transparency, total P,<br />

total N, chlorophyll-a,<br />

phaeophytin, total<br />

alkalinity, field<br />

parameters (pr<strong>of</strong>ile DO,<br />

pH, temperature at<br />

deepest point); Bacteria<br />

sampling at public<br />

beaches to assess<br />

suitability <strong>for</strong> water<br />

contact recreation.<br />

17 ponds Add Fox<br />

Delete Perch<br />

Same, consider if <strong>the</strong>re is a<br />

cost savings associated with<br />

dropping total N (although<br />

data consistency may be<br />

important to SMAST<br />

program)<br />

Data indicate that ponds<br />

are P limited (N:P ratio<br />

is high)<br />

(Fox) Provide guidance<br />

to homeowners<br />

regarding potential<br />

benefits <strong>of</strong> mixing.<br />

(Perch) Problematic<br />

access, natural<br />

progression to wetland<br />

well underway<br />

Frequency Variable At least monthly (May –<br />

October) <strong>for</strong> all ponds.<br />

Biweekly pr<strong>of</strong>ile and water<br />

quality sampling<br />

recommended <strong>for</strong> Stillwater<br />

and Lovers (to support<br />

alum assessment), and o<strong>the</strong>r<br />

deep ponds (Goose, White,<br />

Schoolhouse, Barclays).<br />

Matrix Water column Water column, add limited<br />

sediment testing in ponds<br />

considered <strong>for</strong> alum<br />

treatment to quantify labile<br />

phosphorus.<br />

Increased frequency will<br />

support more robust<br />

averages and better<br />

comparisons to<br />

ecoregional criteria.<br />

Need to evaluate<br />

sediment phosphorus<br />

flux<br />

EcoLogic LLC and 27<br />

November 20, 2003 Rev. 3<br />

Stearns & Wheler LLC