Basic Energy Modeling and Comparative Runs<br />

SD Wizard: Step 2<br />

DAYLIT ZONES SCREENS:<br />

The Daylit Zones Screens are similar to the Skylights Screen. They will appear if you have Yes<br />

selected in the Daylight box on Screen 1. They allow you to adjust the settings for each type of<br />

floor (ground, middle / typical, and top). Selecting daylighting zones is important and should<br />

be done carefully and accurately so that <strong>eQUEST</strong> can correctly calculate the amount of<br />

energy that will be saved through the use of natural light and photo sensors that regulate when<br />

the electric lights are being used in a building. As with any of the other screens, if you do not<br />

understand all of the settings or are unsure as to what your building will exactly use or need,<br />

then accept the <strong>eQUEST</strong> defaults. You will be able to return to the wizard and change these<br />

options later, as well as use other wizards to modify the settings and create comparative runs.<br />

If you do not want daylighting to be incorporated into your base energy model, you can return<br />

to Screen 1 and select No in the Daylighting box before continuing through the wizard. There is<br />

another feature in <strong>eQUEST</strong> (the EEM Wizard) that will allow you to compare daylit vs. non-daylit<br />

energy models. We will be discussing this wizard later in this module.<br />

MODULE TEXT<br />

HVAC AND DHW SCREENS:<br />

<strong>eQUEST</strong> contains much information about the type and specifications of many HVAC systems<br />

or combinations of systems. Based on earlier input information, <strong>eQUEST</strong> will display certain<br />

screens giving you the opportunity to adjust the HVAC and DHW systems you have selected for<br />

your energy model. Most architects will not need to make many changes at this stage. At a<br />

later point, consulting a mechanical engineer about refining these settings to more accurately<br />

match your building design might be a good idea. Remember to record the changes that you<br />

make on your SD Wizard Form to assist yourself and others that may return to the model at a<br />

later date.<br />

Created by Integrated Design Lab—Bozeman 25