Tap-off boxes<br />
WITH AC 23A SWITCH DISCONNECTOR AND FUSE CARRIER : BOLT-ON TYPE<br />
Aluminium<br />
NH 1000A 1250A 1600A 2000A 2250A 2500A 3200A 4000A 4500A<br />
125A 00 90601811 90601831 90601831 90601841 90621811 90621831 90621831 90621841 90621851<br />
250A 1 90601812 90601832 90601832 90601842 90621812 90621832 90621832 90621842 90621852<br />
400A 2 90601813 90601833 90601833 90601843 90621813 90621833 90621833 90621843 90621853<br />
630A 3 90601814 90601834 90601834 90601844 90621814 90621834 90621834 90621844 90621854<br />
800A 4 90601815 90601835 90601835 90601845 90621815 90621835 90621835 90621845 90621855<br />
1000A 4 90601816 90601836 90601836 90601846 90621816 90621836 90621836 90621846 90621856<br />
1250A 4 90601837 90601837 90601847 90621817 90621837 90621837 90621847 90621857<br />
single bar<br />
double bar<br />
Copper<br />
NH 1000A 1250A 1600A 2000A 2500A 3200A 3200A 4000A 5000A<br />
125A 00 95601801 95601811 95601821 95601831 95601841 95621821 95621821 95621831 95621851<br />
250A 1 95601802 95601812 95601822 95601832 95601842 95621822 95621822 95621832 95621852<br />
400A 2 95601803 95601813 95601823 95601833 95601843 95621823 95621823 95621833 95621853<br />
630A 3 95601804 95601814 95601824 95601834 95601844 95621824 95621824 95621834 95621854<br />
800A 4 95601805 95601815 95601825 95601835 95601845 95621825 95621825 95621835 95621855<br />
1000A 4 95601806 95601816 95601826 95601836 95601846 95621826 95621826 95621836 95621856<br />
1250A 4 95601817 95601827 95601837 95601847 95621827 95621827 95621837 95621857<br />
single bar<br />
double bar<br />
The direction of the disconnector (fuses) must be specifi ed when ordering.<br />
The bolted boxes are to be installed when the busbar is disconnected and not<br />
energized.<br />
For operating voltages (Ue) different from 400V, please contact Zucchini.<br />
A<br />
Fuses not included. See Legrand catalogue.<br />
E<br />
C<br />
Rated insulating AC voltage Ui [V] 1000<br />
Rated impulse withstand voltage Uimp [kV] 12<br />
Type of rated duty<br />
AC23A<br />
Rated conditional short circuit current [kA] 100<br />
CEI EN 60947-3<br />
B<br />
D<br />
If required, the box can be supplied so that It can be used with a<br />
DPX moulded case circuit breaker (MCCB) or empty.<br />
DIMENSIONS OF THE BOX<br />
Box rating 125A to 400A 630A 800A to 1250A<br />
(A) [mm] 285 400 450<br />
(B) [mm] 600 750 1050<br />
(C) [mm] 245 280 300<br />
(D) [mm] 95 115 115<br />
(E) [mm] 530 680 750<br />
88 HIGH RATING