2. If a beam is under its service load, it would behave similarly on application<br />

of a superimposed load. The presence or absence of acoustic emissions<br />

during this further loading and unloading might indicate the condition of the<br />

beam.<br />

3. If a beam under service load showed no acoustic emission activity during<br />

further loading, but did so at a later date when loaded to the same level, then<br />

the strength must have decreased during that time interval.<br />

As well, Williams noted similar behavior on testing of ordinary prestressed<br />

concrete beams, and suggested that these techniques could be used to<br />

evaluate any type of concrete structure, as long as acoustic emissions not<br />

connected with beam damage could be eliminated.<br />