EMC<br />

Test Results<br />

Leakage and Impedance<br />

All <strong>icotek</strong> shield clamps have been tested utilizing<br />

various frequency ranges and in all tests there was<br />

minimal leakage resistance.<br />

<strong>icotek</strong> EMC shield clamps are proven to absorb<br />

electromagnetic interferences.<br />

LF|SKL 8-11<br />

Impedance Z [Ohm]<br />

200<br />

160<br />

120<br />

80<br />

4.1<br />

Electrical impedance values:<br />

- <strong>from</strong> 10 kHz to 100 MHz under 20 Ohm<br />

- up to 1.000 MHz under 120 Ohm<br />

The unique design of <strong>icotek</strong> shield clamps<br />

effectively reduce high frequency interferences.<br />

40<br />

0<br />

o 200 400 600 800 1000<br />

Leakage absorption [dB]<br />

45<br />

40<br />

35<br />

30<br />

Frequency [MHz]<br />

25<br />

20<br />

15<br />

10<br />

Contact Area<br />

5<br />

0<br />

0o 100 200 300 400 500 600 700 800 900 1000 1000<br />

Frequency [MHz]<br />

The SKL shield clamps offer a large contact area to<br />

the cable shield (see figure A).<br />

In comparison to conventional shield clamps, an up<br />

to 50% higher contact area is achieved when using<br />

the SKL product line.<br />

SF|SKL 6-8<br />

Impedance Z [Ohm]<br />

200<br />

180<br />

160<br />

140<br />

120<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

0o 100 200 300 400 500 600 700 800 900 1000 1000<br />

Leakage absorption [dB]<br />

45<br />

40<br />

35<br />

30<br />

Frequency [MHz]<br />

Figure A: SKL-line<br />

Figure B: Conventional<br />

systems<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

0o 100 200 300 400 500 600 700 800 9001000<br />

1000<br />

Frequency [MHz]<br />

128