Chapter Content 4.2<br />

IP55<br />

IP55<br />

EMC <strong>Cable</strong> <strong>Entry</strong> Frames<br />

EMC-KEL-DS<br />

EMC Split <strong>Cable</strong> Gland<br />

EMC-KVT-DS<br />

EMC <strong>Cable</strong> <strong>Entry</strong> Frames<br />

EMC-KEL<br />

170 – 171 172 – 173<br />

174 – 175<br />

EMC Grommets, small<br />

EMC-KT<br />

EMC Grommets, large<br />

EMC-KT<br />

176 177<br />

Test Results<br />

Conducted and Field-bound Disturbances<br />

45<br />

Ableitdämpfung (Schirmgebunden)<br />

Dissipating Absorption (conducted)<br />

Conducted Disturbances<br />

4.2<br />

Absorption<br />

Dämpfung<br />

(dB)<br />

(dB)<br />

40<br />

35<br />

30<br />

25<br />

20<br />

EMC-KEL<br />

EMV-KEL<br />

The EMC-KEL shows during cable-bound disruptions<br />

stable attenuation values up to 40 dB in the<br />

frequency ranges <strong>from</strong> 9 kHz to 30 MHz.<br />

15<br />

cable sheath<br />

exposed cable shield<br />

10<br />

5<br />

9 kHz 30 MHz<br />

0<br />

0,001 0,01<br />

0,1 1 10 100 1000 3000<br />

Frequency Frequenz (MHz)<br />

(MHz)<br />

100<br />

Ableitdämpfung (Feldgebunden)<br />

Dissipating Absorption (field-bound)<br />

Field-bound Disturbances<br />

Dämpfung<br />

Absorption<br />

(dB)<br />

(dB)<br />

80<br />

60<br />

40<br />

20<br />

EMV-KEL: EMC-KEL:<br />

Je Depending nach Anwendung on<br />

mind. 34 dB<br />

the application<br />

at least 34 dB<br />

Regarding the field-bound disturbances and depending<br />

on the application, in the relevant frequency ranges up<br />

to 3 GHz constant measurements of at least 34 dB have<br />

been achieved. Below the attenuation range, the curve<br />

falls only at extreme high frequencies above 3 GHz.<br />

0<br />

0,001 0,01 0,1 1 10 100 1000 3000<br />

Frequenz Frequency (MHz)<br />

(MHz)<br />