4.2<br />

EMC <strong>Cable</strong> <strong>Entry</strong> <strong>Systems</strong><br />

Solutions for Conducted and Field-Bound Disturbances<br />

IP55<br />

The industrial process technology demands increasing security against<br />

disturbances for electrical MCR facilities (measure, control, regulate).<br />

Special emphasis is being placed on the derivation of electromagnetic<br />

interference. A distinction is made between screening-related and field-related<br />

disturbances.<br />

Screening-related interference is being transmitted directly <strong>from</strong> the<br />

source of interference to the cable shield of the supply or signal leads and<br />

then to the susceptible device. All capacitive and inductive influences of<br />

electrical or magnetic fields are called field bound disturbances.<br />

The field bound disturbances are being transferred, for example as a<br />

cable’s electromagnetic field, <strong>from</strong> the source of interference to the<br />

susceptible device and received there, for instance, by a head acting as an<br />

antenna.<br />

A large contact area of the cable shield for the derivation of the inter ference<br />

to a conductive housing wall combined with the shielding of the housing<br />

interior generally offers a good solution for both types of interference.<br />

In case of conducted as well as field bound EMC disturbances, our cable<br />

entry system offers an effective way to divert and block those disturbances.<br />

The key feature of <strong>icotek</strong>’s system is the split frame and split grommets<br />

which provide quick, convenient and cost effective routing of pre-terminated<br />

and multi-conductor cables, hoses and conduits. The split frame and<br />

split grommets alleviate the need to cut and re-wire pre-terminated cables.<br />

Therefore, cable warranties are unaffected.<br />

4.2<br />

Space saving <strong>icotek</strong> solution:<br />

EMC cable entry frame<br />

EMC-KEL-U 24|10<br />

normal EMC cable glands<br />

168