<strong>Configuration</strong> <strong><strong>Soft</strong>ware</strong><br />

<strong>Flexi</strong> <strong>Soft</strong> <strong>Designer</strong><br />

<strong>Configuration</strong> help<br />

O N L I N E H E L P<br />

GB


<strong><strong>Soft</strong>ware</strong> status described<br />

<strong><strong>Soft</strong>ware</strong> / Tool Function Status<br />

<strong>Flexi</strong> <strong>Soft</strong> <strong>Designer</strong> <strong>Configuration</strong> software V1.3.0 SP1<br />

Copyright<br />

Copyright © 2011<br />

SICK AG, Waldkirch<br />

Industrial Safety Systems<br />

Erwin-<strong>Sick</strong>-Str. 1<br />

79183 Waldkirch<br />

Germany<br />

Online Help<br />

<strong>Flexi</strong> <strong>Soft</strong> <strong>Designer</strong><br />

This work is subject to copyright. SICK AG reserves the associated rights. Duplication of this work, in whole or in<br />

part, is only permitted subject to the limits of the statutory provisions of the Copyright Act. Modification or<br />

expurgation of this work is prohibited without the express written permission of SICK AG.<br />

2 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8014174/2011-04-06<br />

Subject to change without notice


Online Help<br />

<strong>Flexi</strong> <strong>Soft</strong> <strong>Designer</strong><br />

Table of contents<br />

Table of contents<br />

1 About this document ......................................................................................................... 4<br />

2 <strong>Flexi</strong> <strong>Soft</strong> <strong>Designer</strong> – Online Help .................................................................................... 5<br />

2.1 About <strong>Flexi</strong> <strong>Soft</strong> <strong>Designer</strong> <strong>Flexi</strong> <strong>Soft</strong> <strong>Designer</strong> ..................................................... 5<br />

3 Hardware configuration .................................................................................................... 6<br />

3.1 Starting the project ............................................................................................... 6<br />

3.2 Selecting the main unit ......................................................................................... 6<br />

3.3 Selecting the expansion modules ........................................................................ 6<br />

3.4 Selecting the input elements ............................................................................... 7<br />

3.5 Selecting the actuators/displays/outputs ........................................................... 7<br />

3.6 Assigning tag names ............................................................................................. 8<br />

4 Editing the hardware configuration ................................................................................ 9<br />

4.1 Deleting and moving modules .............................................................................. 9<br />

4.2 Deleting or editing an element/discrepancy time/test signal ............................ 9<br />

5 Creating the logical process ..........................................................................................10<br />

5.1 Positioning the input elements ..........................................................................10<br />

5.2 Positioning the function blocks ..........................................................................10<br />

5.3 Positioning the outputs .......................................................................................10<br />

5.4 Simulation ...........................................................................................................11<br />

6 Connecting, transferring and verifying .........................................................................12<br />

7 Report and diagnostics ...................................................................................................13<br />

7.1 Calling and printing the report............................................................................13<br />

7.2 Calling the diagnostics ........................................................................................13<br />

8 Saving the configuration ................................................................................................14<br />

9 Device status values in the <strong>Flexi</strong> <strong>Soft</strong> system ..............................................................15<br />

10 <strong>Flexi</strong> <strong>Soft</strong> <strong>Designer</strong> Extras ..............................................................................................17<br />

10.1 Force mode ..........................................................................................................17<br />

8014174/2011-04-06 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 3<br />

Subject to change without notice


About this document<br />

Chapter 1 Online Help<br />

1 About this document<br />

Function of this document<br />

Target group<br />

Information depth<br />

Important<br />

<strong>Flexi</strong> <strong>Soft</strong> <strong>Designer</strong><br />

Please read this document carefully if you do not have any<br />

previous knowledge of <strong>Flexi</strong> <strong>Soft</strong> <strong>Designer</strong>. It will simplify<br />

your work when dealing with configuration software.<br />

This document will help you when configuring your <strong>Flexi</strong><br />

<strong>Soft</strong> Station, or your <strong>Flexi</strong> Link system. Nevertheless, this<br />

document is no substitute for the <strong>Flexi</strong> <strong>Soft</strong> hardware<br />

operating instructions (document no. 8012478) or the<br />

<strong>Flexi</strong> <strong>Soft</strong> <strong>Designer</strong> operating instructions (document no.<br />

8012480). This document merely serves as a guideline<br />

and not to provide safety-relevant instructions.<br />

The target group for this document consists of people in the<br />

following roles:<br />

Roles Target group<br />

Commissioning and<br />

configuration<br />

Expert personnel, such as<br />

technicians or engineers<br />

This document takes you through the configuration of a <strong>Flexi</strong><br />

<strong>Soft</strong> Station using the <strong>Flexi</strong> <strong>Soft</strong> <strong>Designer</strong> configuration<br />

software.<br />

For information on mounting, installation, maintenance and<br />

troubleshooting, see the <strong>Flexi</strong> <strong>Soft</strong> hardware operating<br />

instructions (document no. 8012478) and the <strong>Flexi</strong> <strong>Soft</strong><br />

<strong>Designer</strong> software operating instructions (document no.<br />

8012480).<br />

You can get further information on <strong>Flexi</strong> <strong>Soft</strong> safety control<br />

and <strong>Flexi</strong> <strong>Soft</strong> <strong>Designer</strong> configuration software from SICK AG,<br />

Division Industrial Safety Systems.<br />

4 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8014174/2011-04-06<br />

Subject to change without notice


Online Help Chapter 2<br />

<strong>Flexi</strong> <strong>Soft</strong> <strong>Designer</strong><br />

<strong>Flexi</strong> <strong>Soft</strong> <strong>Designer</strong> – Online Help<br />

2 <strong>Flexi</strong> <strong>Soft</strong> <strong>Designer</strong> – Online Help<br />

Simple project configuration<br />

2.1 About <strong>Flexi</strong> <strong>Soft</strong> <strong>Designer</strong><br />

<strong>Flexi</strong> <strong>Soft</strong> <strong>Designer</strong> is a tool that allows you to configure your <strong>Flexi</strong> <strong>Soft</strong> Station. It helps you<br />

when selecting and connecting your modules and elements with simple hardware<br />

configuration and the logic editor.<br />

8014174/2011-04-06 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 5<br />

Subject to change without notice


Hardware configuration<br />

Chapter 3 Online Help<br />

3 Hardware configuration<br />

3.1 Starting the project<br />

When you have started <strong>Flexi</strong> <strong>Soft</strong> <strong>Designer</strong>, select Create new project.<br />

3.2 Selecting the main unit<br />

<strong>Flexi</strong> <strong>Soft</strong> <strong>Designer</strong><br />

Now select a main unit from the Modules section. Use the mouse to drag & drop it into the<br />

configuration area or click on the desired main unit CPU0 or to CPU1 if you want to<br />

3.3 Selecting the expansion modules<br />

connect an EFI-compatible SICK<br />

sensor.<br />

After selecting the main unit, select the required expansion modules. You have three selec-<br />

tion options: gateways for integrating into the PLC, I/O modules, and relays. You can<br />

choose between 7 different<br />

gateways, 2 input and output<br />

modules, 4 relay expansions, as<br />

well as a speed monitor for<br />

standstill and drive monitoring.<br />

6 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8014174/2011-04-06<br />

Subject to change without notice


Online Help Chapter 3<br />

<strong>Flexi</strong> <strong>Soft</strong> <strong>Designer</strong><br />

Hardware configuration<br />

3.4 Selecting the input elements<br />

When you have selected all the modules, click on Elements at the bottom left.<br />

Now select your sensors/indicators/inputs from the input elements. Use the mouse to<br />

drag it to the intended module. A green mark appearing on the inputs of the expansion<br />

module indicates that these<br />

inputs can still be used. Double<br />

clicking on the required input<br />

element automatically uses the<br />

first free inputs.<br />

3.5 Selecting the actuators/displays/outputs<br />

In Elements, select Actuators/Displays/Outputs and drag the selected elements to the<br />

desired free outputs in the same way as described in 3.4.<br />

8014174/2011-04-06 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 7<br />

Subject to change without notice


Hardware configuration<br />

Chapter 3 Online Help<br />

3.6 Assigning tag names<br />

<strong>Flexi</strong> <strong>Soft</strong> <strong>Designer</strong><br />

When you have selected your hardware, click on the circle icon on the left next to<br />

your CPU to define or change the tag names for the inputs and outputs. You can now<br />

assign your own names in the<br />

window that opens next.<br />

8 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8014174/2011-04-06<br />

Subject to change without notice


Online Help Chapter 4<br />

<strong>Flexi</strong> <strong>Soft</strong> <strong>Designer</strong><br />

Editing the hardware configuration<br />

4 Editing the hardware configuration<br />

4.1 Deleting and moving modules<br />

To move a module, left click on it and drag it to the desired position while holding down the<br />

left mouse button. To delete it, drag it to the trash can at the bottom left, or right click on<br />

the module and select Remove<br />

module.<br />

4.2 Deleting or editing an element/discrepancy time/test<br />

signal<br />

To delete an element, right click on the element to be deleted and select Remove. To edit<br />

an element, right click on the element and select Edit. Among other things, this is where you<br />

can configure the discrepancy<br />

time and specify whether the<br />

element is connected to test<br />

outputs. The discrepancy time is<br />

the maximum period for which<br />

both inputs can display disallowed<br />

statuses during a dual-channel<br />

evaluation, without the safety<br />

logic evaluating that status as an<br />

8014174/2011-04-06 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 9<br />

Subject to change without notice<br />

error.<br />

The test signals are used to identify short circuits. Different test signal patterns are<br />

created for X1 and X2. In the event of a short circuit, only one of the signal patterns arrives<br />

at the connected inputs, therefore identifying the short circuit.


Creating the logical process<br />

Chapter 5 Online Help<br />

5 Creating the logical process<br />

5.1 Positioning the input elements<br />

5.2 Positioning the function blocks<br />

<strong>Flexi</strong> <strong>Soft</strong> <strong>Designer</strong><br />

In the Inputs window in the logic<br />

editor, select your input<br />

elements on the left and drag<br />

them to the configuration area.<br />

You can hold down Shift while<br />

left clicking to select several<br />

inputs simultaneously.<br />

When you have positioned the input elements in the configuration area, select the<br />

5.3 Positioning the outputs<br />

required function blocks on the<br />

left under Function blocks and<br />

connect them with the input<br />

elements by dragging a<br />

connection line between them.<br />

The function blocks can be<br />

edited by right clicking on them.<br />

The function block is described<br />

in the info folder in the Edit<br />

window.<br />

Now drag the output elements<br />

from the Outputs window on the<br />

left to the configuration area<br />

and connect it with the function<br />

blocks.<br />

10 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8014174/2011-04-06<br />

Subject to change without notice


Online Help Chapter 5<br />

<strong>Flexi</strong> <strong>Soft</strong> <strong>Designer</strong><br />

Creating the logical process<br />

5.4 Simulation<br />

It is possible to simulate the pro-<br />

grammed logic offline in the<br />

logic editor.<br />

Click on the Start simulation<br />

mode icon ( ) in the toolbar to<br />

activate the simulation mode.<br />

The background of the logic<br />

editor turns green and the simu-<br />

lation toolbar appears.<br />

To start a simulation of the logic, click on the green Start button for a full-speed (almost<br />

real-time) simulation. The timer indicates the time passed. The timer can be reset by<br />

clicking the blue Reset button. To stop a simulation, click on the red Stop button.<br />

8014174/2011-04-06 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 11<br />

Subject to change without notice


Connecting, transferring and<br />

verifying<br />

Chapter 6 Online Help<br />

6 Connecting, transferring and verifying<br />

<strong>Flexi</strong> <strong>Soft</strong> <strong>Designer</strong><br />

When you have configured the hardware and the logic in <strong>Flexi</strong> <strong>Soft</strong> <strong>Designer</strong> and checked it<br />

for correctness, click on the Connect button to establish a<br />

connection to your <strong>Flexi</strong> <strong>Soft</strong> system. You can then transfer your project to the <strong>Flexi</strong> <strong>Soft</strong><br />

system and verify it. Transfer the configuration by clicking on the Transfer button.<br />

Enter SICKSAFE as the password in the window that appears. Then click on<br />

Log in. As long as the <strong>Flexi</strong> <strong>Soft</strong> system is not verified, the application will not start auto-<br />

matically when the power is switched on.<br />

To do this, click on the Receive and Compare <strong>Configuration</strong> icon.<br />

The system opens the Upload and verify result window. If the configuration displayed here<br />

is the one you expected, select Yes for Set device to verified? near the bottom of the<br />

screen. The system is now verified.<br />

As soon a project has been verified by an authorized customer, the maintenance techni-<br />

cian can download the project with his/her password. (For more information on this<br />

subject, see the <strong>Flexi</strong> <strong>Soft</strong> <strong>Designer</strong> operating instructions 8012480)<br />

12 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8014174/2011-04-06<br />

Subject to change without notice


Online Help Chapter 7<br />

<strong>Flexi</strong> <strong>Soft</strong> <strong>Designer</strong><br />

Report and diagnostics<br />

7 Report and diagnostics<br />

The standard Report view provides a full report for the current project and all configuration<br />

settings, including logic programming and wiring. You can define the scope of the report<br />

for yourself. And you can also enter additional notes on your project.<br />

7.1 Calling and printing the report<br />

To call the report, press the Report button. You can then select the scope of the report<br />

7.2 Calling the diagnostics<br />

from the list on the left. Press<br />

the Refresh report button. The<br />

report is generated and<br />

displayed on the right.<br />

The top half of the Diagnostics window has a list all the messages, information, warnings<br />

and error messages in your system. Clicking on the entries in the list displays details on<br />

the selected message in the<br />

lower half of the window.<br />

Click on the Diagnostics button in the menu bar to switch to the standard Diagnostics<br />

view. The toolbar contains the following commands:<br />

Click on Refresh to export the current list of messages from the system.<br />

8014174/2011-04-06 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 13<br />

Subject to change without notice


Saving the configuration<br />

Chapter 8 Online Help<br />

8 Saving the configuration<br />

<strong>Flexi</strong> <strong>Soft</strong> <strong>Designer</strong><br />

At the end of your project, you can save it. To do this, click on the Project button and<br />

select Save.<br />

14 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8014174/2011-04-06<br />

Subject to change without notice


Online Help Chapter 9<br />

<strong>Flexi</strong> <strong>Soft</strong> <strong>Designer</strong><br />

Device status values in the <strong>Flexi</strong> <strong>Soft</strong><br />

system<br />

9 Device status values in the <strong>Flexi</strong> <strong>Soft</strong> system<br />

The <strong>Flexi</strong> <strong>Soft</strong> system recognizes different device status values during operation. Some<br />

device status values require intervention by the user. The following table provides a<br />

summary of typical device status values for the <strong>Flexi</strong> <strong>Soft</strong> system.<br />

CPU<br />

MS LED<br />

� Red (1 Hz)<br />

MS LED<br />

� Red (1 Hz)<br />

MS LED<br />

� Green<br />

(1 Hz)<br />

CV LED<br />

� Yellow<br />

(1 Hz)<br />

MS LED<br />

� Green<br />

(1 Hz)<br />

CV LED<br />

� Yellow<br />

MS LED<br />

� Green<br />

MS LED<br />

� Green<br />

Expansion<br />

modules (EM)<br />

MS LED for all EMs<br />

� Red/Green<br />

(1 Hz)<br />

with firmware V1.xx<br />

� Red (1 Hz)<br />

with firmware V2.xx<br />

MS LED for an EM<br />

� Red/Green<br />

(1 Hz) with firmware<br />

V1.xx<br />

MS LED for an EM<br />

� Red/Green<br />

(1 Hz) with firmware<br />

V2.xx<br />

MS LED<br />

� Green (1 Hz)<br />

MS LED<br />

� Green (1 Hz)<br />

MS LED<br />

� Green<br />

MS LED for an EM<br />

� Red (1 Hz)<br />

with firmware V1.xx<br />

MS LED for an EM<br />

� Red/Green<br />

(1 Hz)<br />

with firmware ≥ V2.xx<br />

Q1 … Q4<br />

� Green (1 Hz)<br />

Possible reason Actions<br />

Expansion module missing Add the missing modules as specified<br />

Module with flashing LED is wrong<br />

type or wrong version<br />

Too many EMs connected<br />

System is idle,<br />

configuration not yet verified<br />

System is idle,<br />

<strong>Configuration</strong> verified<br />

System running, no error detected ---<br />

No power supply for expansion<br />

module<br />

by the configuration<br />

Change the modules so that they<br />

match the configuration<br />

Start application in <strong>Flexi</strong> <strong>Soft</strong> <strong>Designer</strong><br />

Start application in <strong>Flexi</strong> <strong>Soft</strong> <strong>Designer</strong><br />

Check the power supply<br />

A1 = 24 V / A2 = 0 V<br />

When the reason for the error has<br />

been removed, the error disappears<br />

automatically after around 8 seconds.<br />

8014174/2011-04-06 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 15<br />

Subject to change without notice


Device status values in the<br />

<strong>Flexi</strong> <strong>Soft</strong> system<br />

Chapter 9 Online Help<br />

MS LED<br />

� Green<br />

MS LED<br />

� Green<br />

MS LED<br />

� Green<br />

MS LED<br />

� Red<br />

MS LED<br />

� Red<br />

MS LED<br />

� Red (2 Hz)<br />

MS LED for an EM<br />

� Red (1 Hz)<br />

with firmware V1.xx<br />

MS LED for an EM<br />

� Red/Green<br />

(1 Hz)<br />

with firmware ≥ V2.xx<br />

Q1,Q2,Q3 or Q4<br />

� Green (1 Hz)<br />

MS LED for an EM<br />

� Red (1 Hz)<br />

with firmware V1.xx<br />

MS LED for an EM<br />

� Red/Green<br />

(1 Hz)<br />

with firmware ≥ V2.xx<br />

I1, I2, I3, I4, I5, I6, I7<br />

or I8<br />

� Green (1 Hz)<br />

MS LED for an EM<br />

� Red (1 Hz)<br />

with firmware V1.xx<br />

MS LED for an EM<br />

� Red/Green<br />

(1 Hz)<br />

with firmware ≥ V2.xx<br />

I1 + I2 or I3 + I4 or I5<br />

+ I6<br />

or I7 + I8<br />

� Green (1 Hz)<br />

MS LED<br />

� Red<br />

MS LED<br />

� Red (2 Hz)<br />

MS LED<br />

� Red<br />

Short circuit in the output wiring Check the output wiring.<br />

Short circuit at 24 V in the wiring<br />

for tested sensors.<br />

• Defective safety mat<br />

• Defective testable<br />

<strong>Flexi</strong> <strong>Soft</strong> <strong>Designer</strong><br />

To reset the error, use the logic to<br />

deactivate the affected outputs or<br />

reset the CPU module by disconnect-<br />

ing it from the power source and then<br />

reconnecting it.<br />

16 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8014174/2011-04-06<br />

Subject to change without notice<br />

sensor<br />

• Connection between<br />

cable and safety mat<br />

interrupted at I1, I2, …<br />

or I8<br />

• Short circuit at 24 V in<br />

the wiring for tactile<br />

switches<br />

Discrepancy error for dual-channel<br />

inputs when the LEDs flash for the<br />

input pair: I1/I2, I3/I4, I5/I6, I7/I8<br />

No power supply 0 V for XTIO<br />

Internal error in the EM<br />

Internal error in the main unit<br />

Internal error in the expansion<br />

module<br />

Internal error in the main unit or in<br />

the system<br />

Check the input wiring.<br />

Replace the tested sensor.<br />

To reset the error, use the logic to<br />

deactivate the affected inputs or reset<br />

the CPU module by disconnecting it<br />

from the power source and then<br />

reconnecting it.<br />

Check the wiring for the affected input.<br />

Check the connected sensor to ensure<br />

that both inputs switch within the<br />

discrepancy time.<br />

To reset the error, deactivate the<br />

affected inputs or restart the CPU.<br />

Check the power supply for the EM (0 V)<br />

Restart the system. If the error<br />

persists, swap the modules<br />

Check the installation. Restart the<br />

system. If the error persists, swap the<br />

module with the flashing LED<br />

Check the installation. Restart the<br />

system. If the error persists, swap the<br />

module with the flashing LED


Online Help Chapter 10<br />

<strong>Flexi</strong> <strong>Soft</strong> <strong>Designer</strong><br />

<strong>Flexi</strong> <strong>Soft</strong> <strong>Designer</strong> Extras<br />

10 <strong>Flexi</strong> <strong>Soft</strong> <strong>Designer</strong> Extras<br />

10.1 Force mode<br />

In force mode, you can use the software to set the inputs for logic function blocks for a <strong>Flexi</strong><br />

<strong>Soft</strong> system to High or Low while the system is online, regardless of their actual status. The<br />

logic then behaves exactly as if the affected inputs actually have the corresponding status.<br />

Click on Connect to connect to your <strong>Flexi</strong> <strong>Soft</strong> system. Then click in the Hardware con-<br />

figuration view on the Start application button.<br />

Switch to the Logic editor and click on the Start Force Mode button ( ). The system<br />

opens a dialog in which you can enter the time after which force mode is quitted automa-<br />

tically if no further actions are triggered. Select the required time from the selection list<br />

and click on OK. Force mode is started and the background color of the logic editor<br />

changes to red. Left click on the input to change its status.<br />

8014174/2011-04-06 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 17<br />

Subject to change without notice


8014174/2011-04-06<br />

Australia<br />

Phone +61 3 9497 4100<br />

1800 33 48 02 – toll-free<br />

E-mail sales@sick.com.au<br />

Belgium/Luxembourg<br />

Belgium/Luxembourg<br />

Phone +32 (0)2 466 55 66<br />

E-mail info@sick.be<br />

Brasil<br />

Brasil<br />

Phone +55 11 3215 -4900<br />

E-mail sac@sick.com.br<br />

Ceská Ceská Republika<br />

Republika<br />

Phone +420 2 57 91 18 50<br />

E-mail sick@sick.cz<br />

China<br />

China<br />

Phone +852-2763 6966<br />

E-mail ghk@sick.com.hk<br />

Danmark<br />

Danmark<br />

Phone +45 45 82 64 00<br />

E-mail sick@sick.dk<br />

Germany<br />

Germany<br />

Phone +49,2115301 -301<br />

E-mail kundenservice@sick.de<br />

España España<br />

España<br />

Phone +34 93 480 31 00<br />

E-mail info@sick.es<br />

France<br />

France<br />

Phone +33 1 64 62 35 00<br />

E-mail info@sick.fr<br />

Great Great Britain<br />

Britain<br />

Phone +44 (0)1727 831121<br />

E-mail info@sick.co.uk<br />

India<br />

India<br />

Phone +91 -22 -4033 8333<br />

E-mail info@sick-india.com<br />

Israel<br />

Israel<br />

Phone +972-4-999-0590<br />

E-mail info@sick-sensors.com<br />

Italia Italia<br />

Italia<br />

Phone +39 02 27 43 41<br />

E-mail info@sick.it<br />

Japan<br />

Japan<br />

Phone +81 (0)3 3358 1341<br />

E-mail support@sick.jp<br />

Nederlands<br />

Nederlands<br />

Phone +31 (0)30,229 25 44<br />

E-mail info@sick.nl<br />

Norge Norge<br />

Norge<br />

Phone +47 67 81 50 00<br />

E-mail austefjord@sick.no<br />

SICK AG | Waldkirch | Germany | www.sick.com<br />

Austria<br />

Austria<br />

Phone +43 (0)22 36 62 28 8-0<br />

E-mail: office@sick.at<br />

Polska<br />

Polska<br />

Phone +48 22,837 40 50<br />

E-mail info@sick.pl<br />

Republic Republic of of Korea<br />

Korea<br />

Phone +82-2 786 6321/4<br />

E-mail info@sickkorea.net<br />

Republika Republika Slovenija<br />

Slovenija<br />

Phone +386 (0)1 -47 69,990<br />

E-mail office@sick.si<br />

România<br />

România<br />

Phone +40 356 171 120<br />

E-mail office@sick.ro<br />

Russia<br />

Russia<br />

Phone +7 495 775 05 34<br />

E-mail info@sick-automation.ru<br />

Switzerland<br />

Switzerland<br />

Phone +41 41,619 29 39<br />

E-mail: contact@sick.ch<br />

Singapore<br />

Singapore<br />

Phone +656744 3732<br />

E-mail admin@sicksgp.com.sg<br />

South South South Africa<br />

Africa<br />

Phone +2711,472 3737<br />

E-mail info@sickautomation.co.za<br />

Suomi<br />

Suomi<br />

Phone +358 -9 -25 15,800<br />

E-mail sick@sick.fi<br />

Sverige<br />

Sverige<br />

Phone +46 10,110 10 00<br />

E-mail info@sick.se<br />

Taiwan<br />

Taiwan<br />

Phone +886 2 2375 -6288<br />

E-mail sales@sick.com.tw<br />

Türkiye<br />

Türkiye<br />

Phone +90 216 528 50 00<br />

E-mail info@sick.com.tr<br />

United United Arab Arab Emirates<br />

Emirates<br />

Phone +971 4 8865 878<br />

E-mail info@sick.ae<br />

USA/Canada/México<br />

USA/Canada/México<br />

Phone +1 (952)941 -6780<br />

1 800-325-7425 – toll-free<br />

E-mail info@sickusa.com<br />

More representatives and agencies<br />

at www.sick.com<br />

www.sick.com