A flow control generally defines the<br />
downstream end of a sub-catchment, with<br />
the flow control situated at the lowest<br />
topographical point within the subcatchment<br />
in locations that are accessible for<br />
inspection and maintenance.<br />
Concept <strong>Design</strong> drawings should identify<br />
sub-catchment boundaries with associated<br />
storage and flow control locations<br />
throughout the development.<br />
Flow control with<br />
contolled discharge<br />
from one catchment to<br />
the next<br />
Concept <strong>Design</strong><br />
C1<br />
C4<br />
C3<br />
C2<br />
36<br />
Sub-catchments are generally defined by flow<br />
controls. Flows are conveyed from one subcatchment<br />
to the next.<br />
<strong>Design</strong> Note:<br />
Integrating storage within sub-catchments, as part of site layout, greatly reduces the land<br />
take requirement for attenuation, by exploiting the inherent storage capacity of individual<br />
<strong>SuDS</strong> features.<br />
London Borough of <strong>Hillingdon</strong> <strong>SuDS</strong> D & E <strong>Guide</strong><br />
© 2018 McCloy Consulting & Robert Bray Associates