Cover the connection portion of the refrigerant piping with the pipe<br />
cover and seal them.<br />
If neglecting to do so, moisture occurs on the piping and water will<br />
drip out.<br />
Finishing and fixing<br />
Tie up the piping with wrapping tape, and shape it so that it<br />
conforms to which the pipe is attached.<br />
Fix them with clamps as right figure.<br />
<br />
<br />
<br />
<br />
'15 • SRK-T-171<br />
To cover the connecting portion<br />
with insulation materials, cut upper<br />
Vinyl tape portion and then seal it with insulation<br />
materials.<br />
Insulation<br />
Cover the exterior portion with<br />
Refrigerant piping covering tape and shape the piping<br />
Electrical wiring so it will match the contours of the<br />
Covering tape route that the piping to take. Also<br />
fix the wiring and pipings to the wall<br />
Drain hose<br />
with clamps.<br />
Tapping screw<br />
Forced cooling operation<br />
Turn on a power source again after a while after turn off a power source.<br />
Then press continually the ON/OFF button 5 seconds or more.<br />
Unit ON/OFF button<br />
Fixing to pillar or wall<br />
Conventionally, operate the wireless remote control by<br />
holding in your hand.<br />
Avoid installing it on a clay wall etc.<br />
Screws<br />
– 34–<br />
- 54 -<br />
How to relocate or dispose of the unit<br />
In order to protect the environment, be sure to pump down (recovery<br />
of refrigerant).<br />
Pump down is the method of recovering refrigerant from the indoor<br />
unit to the outdoor unit when the pipes are removed from the unit.<br />
<br />
Connect charge hose to check joint.<br />
Liquid side : Close the liquid valve with hexagon wrench key.<br />
Gas side : Fully open the gas valve.<br />
Carry out cooling operation. (If indoor temperature is low, operate<br />
forced cooling operation.)<br />
After low pressure gauge become 0.01MPa, close the gas valve then<br />
stop cooling operation.<br />
<br />
Insulation of connecting portion<br />
Installation of remote control switch<br />
Mounting method of battery<br />
Uncover the remote control switch, and mount the batteries<br />
[R03(AAA, Micro)2 pieces] in the body regularly.<br />
(Fit the poles with the indication marks, & without<br />
fail)<br />
Battery<br />
+<br />
-<br />
-<br />
+<br />
Cover<br />
CAUTION<br />
Do not use new and<br />
old batteries together.<br />
Earthing work<br />
Earth work shall be carried out without fail in order to prevent electric shock and noise generation.<br />
The connection of the earth cable to the following substances causes dangerous failures, therefore it shall never be done.<br />
City water pipe, Town gas pipe, TV antenna, lightning conductor, telephone line, etc.<br />