-TechManual_SRK05,09,12CR-S,CRR-S,CRP-S
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Item<br />
Model<br />
'15 • SRK-T-171<br />
<strong>SRK05</strong>CR-S6<br />
Indoor unit <strong>SRK05</strong>CR-S6<br />
Outdoor unit SRC05CR-S6<br />
1.80<br />
Fine snow<br />
Stucco white<br />
(8.0Y 9.3/0.1) near equivalent<br />
(4.2Y 7.5/1.1) near equivalent<br />
Liquid line : 0.46<br />
—<br />
Gas line : 0.40<br />
Necessary (Both sides), independent<br />
Max. 15<br />
Max.5 (Outdoor unit is higher)<br />
Max.5 (Outdoor unit is lower)<br />
1.5mm 2 x 3 cores (Including earth cable)<br />
Terminal block (Screw fixing type)<br />
Mounting kit<br />
The pipe length is 5m.<br />
Standards<br />
- -<br />
Cooling capacity (1) W 1465<br />
Power source<br />
1 Phase, 220-240V, 50Hz<br />
Operation<br />
data<br />
Power<br />
consumption<br />
Running<br />
current<br />
Cooling kW 0.400<br />
Cooling<br />
A<br />
Inrush current 10<br />
COP Cooling 3.66<br />
Noise<br />
level<br />
Cooling<br />
Sound level dB(A) 42 50<br />
Power level dB 56 61<br />
Exterior dimensions (Height x Width x Depth) mm 262 x 615 x 210 435 x 645 (+50) x 275<br />
Exterior appearance<br />
(Munsell color)<br />
Net weight kg 6 20<br />
Refrigerant<br />
equipment<br />
Air handling<br />
equipment<br />
Compressor type & Q'ty — GAB046PAA (Rotary type) x 1<br />
Motor (Starting method) kW — PSC<br />
Refrigerant oil l 0.23 (POE [RB68A] or PVE [FVC68D])<br />
Refrigerant (4) kg R410A 0.46 ( Pre-charged up to the piping length of 5m )<br />
Heat exchanger Louver fins & inner grooved tubing Louver fins & inner grooved tubing<br />
Refrigerant control<br />
Capillary tubes<br />
Device control<br />
Microcomputer control<br />
Fan type & Q'ty Cross flow fan x 1 Propeller fan x 1<br />
Motor W 17 22<br />
Air flow Cooling m 3 /min 8.5 23<br />
Fresh air intake Not possible —<br />
Air filter, Quality / Quantity Polypropylene net (washable) x 1 —<br />
Shock & vibration absorber — Cushion rubber (for compressor)<br />
Operation<br />
control<br />
Safety devices<br />
Installation<br />
data<br />
Operation switch Wireless remote control —<br />
Room temperature control Microcomputer thermostat —<br />
Operation display<br />
RUN : Green, TIMER : Yellow<br />
Compressor overheat protection, Overcurrent protection,<br />
Frost protection, Serial signal error protection, Indoor Fan motor error protection,<br />
Cooling overload protection<br />
Refrigerant piping size (O.D) mm Liquid line: φ6.35 (1/4") Gas line: φ9.52 (3/8")<br />
Connecting method<br />
Flare connecting<br />
Attached length of piping<br />
Insulation for piping<br />
Refrigerant line (one way) length<br />
Vertical height difference between<br />
outdoor unit and indoor unit<br />
m<br />
m<br />
Drain hose Connectable (VP 16) —<br />
Power cable —<br />
Recommended breaker size A 10<br />
Size x Core number<br />
Connection wiring<br />
Connecting method<br />
Accessories (included)<br />
Option parts —<br />
Note (1) The data are measured at the following conditions.<br />
Operation<br />
Item<br />
Indoor air temperature<br />
Outdoor air temperature<br />
DB WB DB WB<br />
Cooling 27˚C 19˚C 35˚C 24˚C ISO-T1, JIS C 9612<br />
(2) This air-conditioner is manufactured and tested in conformity with the ISO.<br />
(3) The operation data are applied to the 230V districts respectively.<br />
(4) The refrigerant quantity to be charged includes the refrigerant in 5m connecting piping.<br />
(Purging is not required even for the short piping.)<br />
If the piping length is 5m to 15m, additional refrigerant is 10g per each 1m longer than 5m.