Views
1 week ago

-TechManual_SRK05,09,12CR-S,CRR-S,CRP-S

Item Model '15 •

Item Model '15 • SRK-T-171 SRK05CR-S6 Indoor unit SRK05CR-S6 Outdoor unit SRC05CR-S6 1.80 Fine snow Stucco white (8.0Y 9.3/0.1) near equivalent (4.2Y 7.5/1.1) near equivalent Liquid line : 0.46 — Gas line : 0.40 Necessary (Both sides), independent Max. 15 Max.5 (Outdoor unit is higher) Max.5 (Outdoor unit is lower) 1.5mm 2 x 3 cores (Including earth cable) Terminal block (Screw fixing type) Mounting kit The pipe length is 5m. Standards - - Cooling capacity (1) W 1465 Power source 1 Phase, 220-240V, 50Hz Operation data Power consumption Running current Cooling kW 0.400 Cooling A Inrush current 10 COP Cooling 3.66 Noise level Cooling Sound level dB(A) 42 50 Power level dB 56 61 Exterior dimensions (Height x Width x Depth) mm 262 x 615 x 210 435 x 645 (+50) x 275 Exterior appearance (Munsell color) Net weight kg 6 20 Refrigerant equipment Air handling equipment Compressor type & Q'ty — GAB046PAA (Rotary type) x 1 Motor (Starting method) kW — PSC Refrigerant oil l 0.23 (POE [RB68A] or PVE [FVC68D]) Refrigerant (4) kg R410A 0.46 ( Pre-charged up to the piping length of 5m ) Heat exchanger Louver fins & inner grooved tubing Louver fins & inner grooved tubing Refrigerant control Capillary tubes Device control Microcomputer control Fan type & Q'ty Cross flow fan x 1 Propeller fan x 1 Motor W 17 22 Air flow Cooling m 3 /min 8.5 23 Fresh air intake Not possible — Air filter, Quality / Quantity Polypropylene net (washable) x 1 — Shock & vibration absorber — Cushion rubber (for compressor) Operation control Safety devices Installation data Operation switch Wireless remote control — Room temperature control Microcomputer thermostat — Operation display RUN : Green, TIMER : Yellow Compressor overheat protection, Overcurrent protection, Frost protection, Serial signal error protection, Indoor Fan motor error protection, Cooling overload protection Refrigerant piping size (O.D) mm Liquid line: φ6.35 (1/4") Gas line: φ9.52 (3/8") Connecting method Flare connecting Attached length of piping Insulation for piping Refrigerant line (one way) length Vertical height difference between outdoor unit and indoor unit m m Drain hose Connectable (VP 16) — Power cable — Recommended breaker size A 10 Size x Core number Connection wiring Connecting method Accessories (included) Option parts — Note (1) The data are measured at the following conditions. Operation Item Indoor air temperature Outdoor air temperature DB WB DB WB Cooling 27˚C 19˚C 35˚C 24˚C ISO-T1, JIS C 9612 (2) This air-conditioner is manufactured and tested in conformity with the ISO. (3) The operation data are applied to the 230V districts respectively. (4) The refrigerant quantity to be charged includes the refrigerant in 5m connecting piping. (Purging is not required even for the short piping.) If the piping length is 5m to 15m, additional refrigerant is 10g per each 1m longer than 5m.

Item Model '15 • SRK-T-171 SRK05CRP-S Indoor unit SRK05CRP-S Outdoor unit SRC05CRP-S 2.30 Fine snow Stucco white (8.0Y 9.3/0.1) near equivalent (4.2Y 7.5/1.1) near equivalent Liquid line : 0.46 — Gas line : 0.40 Necessary (Both sides), independent Max. 15 Max.5 (Outdoor unit is higher) Max.5 (Outdoor unit is lower) 1.5mm 2 x 3 cores (Including earth cable) Terminal block (Screw fixing type) Mounting kit The pipe length is 5m. Standards - - Cooling capacity (1) W 1465 Power source 1 Phase, 220-240V, 50Hz Operation data Power consumption Running current Cooling kW 0.490 Cooling A Inrush current 10 COP Cooling 2.99 Noise level Cooling Sound level dB(A) 42 50 Power level dB 56 61 Exterior dimensions (Height x Width x Depth) mm 262 x 615 x 210 435 x 645 (+50) x 275 Exterior appearance (Munsell color) Net weight kg 6 19.5 Refrigerant equipment Air handling equipment Compressor type & Q'ty — GAB046PAA (Rotary type) x 1 Motor (Starting method) kW — PSC Refrigerant oil l 0.23 (POE [RB68A] or PVE [FVC68D]) Refrigerant (4) kg R410A 0.44 ( Pre-charged up to the piping length of 5m ) Heat exchanger Louver fins & inner grooved tubing Louver fins & inner grooved tubing Refrigerant control Capillary tubes Device control Microcomputer control Fan type & Q'ty Cross flow fan x 1 Propeller fan x 1 Motor W 17 22 Air flow Cooling m 3 /min 8.5 20 Fresh air intake Not possible — Air filter, Quality / Quantity Polypropylene net (washable) x 1 — Shock & vibration absorber — Cushion rubber (for compressor) Operation control Safety devices Installation data Operation switch Wireless remote control — Room temperature control Microcomputer thermostat — Operation display RUN : Green, TIMER : Yellow Compressor overheat protection, Overcurrent protection, Frost protection, Serial signal error protection, Indoor Fan motor error protection, Cooling overload protection Refrigerant piping size (O.D) mm Liquid line: φ6.35 (1/4") Gas line: φ9.52 (3/8") Connecting method Flare connecting Attached length of piping Insulation for piping Refrigerant line (one way) length Vertical height difference between outdoor unit and indoor unit m m Drain hose Connectable (VP 16) — Power cable — Recommended breaker size A 10 Size x Core number Connection wiring Connecting method Accessories (included) Option parts — Note (1) The data are measured at the following conditions. Operation Item Indoor air temperature Outdoor air temperature DB WB DB WB Cooling 27˚C 19˚C 35˚C 24˚C ISO-T1, JIS C 9612 (2) This air-conditioner is manufactured and tested in conformity with the ISO. (3) The operation data are applied to the 220V districts respectively. (4) The refrigerant quantity to be charged includes the refrigerant in 5m connecting piping. (Purging is not required even for the short piping.) If the piping length is 5m to 15m, additional refrigerant is 10g per each 1m longer than 5m.

1. Multiple piping type - The Energy Conscious
1. Multiple piping type - The Energy Conscious
A2 35YHA1 - Hitachi Air Conditioning Products
Bedford Tel: 01234 272702 Birmingham Tel: 0121 313 6720 Bristol ...
2010 PRODUCT CATALOGUE
Eco Compact H1 Series - Ferret
VRVIII-S - Brochure - Daikin AC
Bedford Tel: 01234 272702 Birmingham Tel ... - 3D Air Sales Ltd.
2011 Price List - EUR - Mitsubishi Heavy Industries Ltd.
General Product Catalog - Daikin AC
60% reduced - Szathmáry service kft
Multi-Split System Tri-Fold Flyer - Daikin AC
High Performance Air to Water Heat Pump - BVTPartneri.lv
The Multi-talented VRV-S. - Pacific HVAC Air Conditioner
PDF 3.4MB - Con Edison Commercial & Industrial Energy Efficiency ...
Room Air Conditioners: brochure - Ultimate Air
Building Life Begins With You - Sanyo
P-Series Full-line Catalog - Duncklee Cooling & Heating Inc.
Chapter 2 Introduction of Pioneer products
Building Life Begins With You - Monroe Equipment, Inc.
ENGiNEERiNG AND SPECiFiCATioNS GuiDE - Split Air Conditioner