30.07.2018 Views

2002 Replacement Parts Catalog

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Comparison of Cameron Ram-Type Blowout Preventers<br />

Cameron offers a wide range of ram-type BOPs to meet the dynamic needs of the<br />

drilling industry. The Cameron U BOP was initially designed for underwater drilling<br />

and is now the most widely used land BOP. Today, there are more U BOPs in the<br />

field worldwide than any other ram-type BOP in the industry. As technology and the<br />

needs of the drilling industry changed, Cameron responded by developing new<br />

ram-type BOP designs. Cameron introduced the U II BOP for subsea applications and<br />

has since developed the T BOP and the TL, UL and UM models for land and subsea<br />

applications. Regardless of the model, all of the pressure containing components in<br />

Cameron ram-type BOPs are forged to provide added safety and reliability.<br />

Comparison of Cameron Ram-Type BOPs<br />

Description TL BOP UM BOP U BOP<br />

Bore Sizes Working Pressures Working Pressures Working Pressures<br />

7-1/16” - 3000 psi WP 3000 psi WP<br />

- 5000 psi WP 5000 psi WP<br />

- 10,000 psi WP 10,000 psi WP<br />

- 15,000 psi WP 15,000 psi WP<br />

11” - - 3000 psi WP<br />

- 5000 psi WP 5000 psi WP<br />

- 10,000 psi WP 10,000 psi WP<br />

- 15,000 psi WP 15,000 psi WP<br />

13-5/8” - - 3000 psi WP<br />

- - 5000 psi WP<br />

10,000 psi WP 10,000 psi WP 10,000 psi WP<br />

- 15,000 psi WP 15,000 psi WP<br />

16-3/4” - - 3000 psi WP<br />

- - 5000 psi WP<br />

- - 10,000 psi WP<br />

18-3/4” 5000 psi WP - -<br />

10,000 psi WP - 10,000 psi WP<br />

15,000 psi WP - -<br />

20-3/4” - - 3000 psi WP<br />

21-1/4” - - 2000 psi WP<br />

- - 5000 psi WP<br />

- - 10,000 psi WP<br />

26-3/4” - - 3000 psi WP<br />

Side Ram Removal Yes No No<br />

Hydraulic Stud<br />

Tensioning*<br />

Not Required No Available on large sizes<br />

Bonnet Seal Carrier Standard Available Available<br />

Mechanical or<br />

Hydromechanical Locking<br />

Mechanism<br />

RamLocks/ST-Lock/Wedge<br />

locks<br />

Wedgelocks<br />

Wedgelocks<br />

*Not required when using bonnet seal carrier<br />

TC1001 9 © <strong>2002</strong> Cooper Cameron, Cameron Division

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!