© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

2<br />

■ Technical specifications<br />

SINAMICS G120X converters<br />

Open-loop/closed-loop <strong>control</strong> techniques<br />

V/f linear/quadratic/parameterizable<br />

V/f with flux current <strong>control</strong> (FCC)<br />

V/f ECO linear/quadratic<br />

Vector <strong>control</strong>, sensorless<br />

Software functions<br />

Setpoint input, can be parameterized<br />

Fixed frequencies<br />

JOG<br />

Digital motorized potentiometer<br />

(MOP)<br />

Ramp smoothing<br />

Extended ramp-function generator<br />

(with ramp smoothing OFF3)<br />

Slip compensation<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

16, parameterizable<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

Switchable drive data sets (DDS) ✓ (4)<br />

Switchable command data sets (CDS) ✓ (2)<br />

Free function blocks (FFB) for ✓ (for frame sizes FSA to FSG)<br />

logical and arithmetic operations<br />

Flying restart<br />

Automatic restart<br />

after line supply failure or operating<br />

fault (AR)<br />

Technology <strong>control</strong>ler (internal PID)<br />

Energy saving display<br />

✓<br />

✓<br />

✓<br />

✓<br />

3 additional, free PID <strong>control</strong>lers ✓<br />

Hibernation mode with internal/ ✓<br />

external PID <strong>control</strong>ler<br />

Belt monitoring with and without<br />

sensor (load torque monitoring)<br />

Dry-running/overload protection<br />

monitoring (load torque monitoring)<br />

Deragging<br />

Thermal motor protection<br />

Thermal converter protection<br />

Motor identification<br />

Auto-ramping (V dc_max <strong>control</strong>ler)<br />

Kinetic buffering (V dc_min <strong>control</strong>ler)<br />

Braking functions<br />

•DC braking<br />

• Compound braking<br />

✓<br />

✓<br />

✓<br />

✓ (I 2 t, sensor: PTC, Pt100, Pt1000, KTY and bimetal)<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

2/26 Siemens D 31.5 · March <strong>2020</strong><br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong>