12.01.2021 Views

motion-control-drives-D31-5-complete-English-2020-03-Update-2020-08

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

2<br />

■ Technical specifications<br />

6SL32.0-.YH50-.C.0 6SL32.0-.YH52-.C.0 6SL32.0-.YH54-.C.0 6SL3220-.YH56-.C.0 6SL3220-.YH58-.C.0<br />

Type of voltage 3AC 3AC 3AC 3AC 3AC<br />

Line voltage V 500 ... 690 500 ... 690 500 ... 690 500 ... 690 500 ... 690<br />

Output current at line voltage 690 V<br />

• without overload rated value A 175 213 256 368 400<br />

• with low overload rated value A 171 2<strong>08</strong> 250 330 385<br />

• with high overload rated value A 144 171 2<strong>08</strong> 272 314<br />

• maximum A 231 281 338 487 529<br />

Supplied active power at rated value of<br />

output voltage and at line voltage 690 V<br />

• with low overload kW 160 200 250 315 355<br />

• with high overload kW 132 160 200 250 315<br />

Supplied active power [hp] at rated<br />

value of output voltage and at line<br />

voltage 600 V<br />

• with low overload hp 150 200 250 350 400<br />

• with high overload hp 150 150 200 250 350<br />

Pulse frequency kHz 2 2 2 2 2<br />

Efficiency 0.98 0.98 0.98 0.98 0.98<br />

Power loss maximum 1) kW 2.94 3.7 4.64 5.402 6.191<br />

Cooling air flow<br />

m³/s 0.21 (26697.89049) 0.21 (26697.89049) 0.21 (26697.89049) 0.362 (46022.07788) 0.362 (46022.07788)<br />

(ft³/h)<br />

1 m measuring surface sound pressure dB 74 74 74 74 74<br />

level maximum<br />

Input current at line voltage 690 V<br />

• with low overload rated value A 175 210 255 343 401<br />

• with high overload rated value A 160 185 225 283 327<br />

for mains supply line<br />

• Type of electrical connection M10 screw M10 screw M10 screw M12 screw M12 screw<br />

• Number of connections 2 2 2 4 4<br />

• Connectable conductor cross-section mm² 35 ... 185 35 ... 185 35 ... 185 35 ... 240 35 ... 240<br />

• Connectable conductor cross-section 2 ... -3 2...-3 2...-3 2...-3 2...-3<br />

(AWG)<br />

for motor supply line<br />

• Type of electrical connection M10 screw M10 screw M10 screw M12 screw M12 screw<br />

• Number of connections 2 2 2 4 4<br />

• Connectable conductor cross-section mm² 35 ... 185 35 ... 185 35 ... 185 35 ... 240 35 ... 240<br />

• Connectable conductor cross-section 2 ... -3 2...-3 2...-3 2...-3 2...-3<br />

(AWG)<br />

Type of electrical connection for PE<br />

M10 screw M10 screw M10 screw M12 screw M12 screw<br />

conductor<br />

Cable length for motor<br />

• shielded maximum 2) m(ft) 150 (492.12598) 150 (492.12598) 150 (492.12598) 150 (492.12598) 150 (492.12598)<br />

Dimensions<br />

•Width mm (in) 305 (12.00787) 305 (12.00787) 305 (12.00787) 548 (21.5748) 548 (21.5748)<br />

•Height mm (in) 999 (39.33071) 999 (39.33071) 999 (39.33071) 1695 (66.73228) 1695 (66.73228)<br />

•Depth mm (in) 360 (14.17323) 360 (14.17323) 360 (14.17323) 393 (15.47244) 393 (15.47244)<br />

Frame size FSG FSG FSG FSH FSH<br />

Weight, approx. kg (lb) 105 (231.48536) 113 (249.12234) 120 (264.5547) 158 (348.33<strong>03</strong>5) 158 (348.33<strong>03</strong>5)<br />

1) Typical values. More information can be found on the Internet at<br />

https://support.industry.siemens.com/cs/document/94059311<br />

2/44 Siemens D 31.5 · March <strong>2020</strong><br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong><br />

2) The values apply with compliance to the EMC category.<br />

For more information, see Maximum permissible motor cable lengths<br />

SINAMICS G120X and on the Internet at<br />

www.siemens.com/sinamics-g120x/documentation