SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

2<br />

■ Technical specifications<br />

6SL32.0-.YE18-.A.0<br />

6SL32.0-.YE18-.U.0<br />

6SL32.0-.YE20-.A.0<br />

6SL32.0-.YE20-.U.0<br />

6SL32.0-.YE22-.A.0<br />

6SL32.0-.YE22-.U.0<br />

6SL32.0-.YE24-.A.0<br />

6SL32.0-.YE24-.U.0<br />

Type of voltage 3AC 3AC 3AC 3AC<br />

Line voltage V 380 ... 480 380 ... 480 380 ... 480 380 ... 480<br />

Output current at line voltage 400 V<br />

• without overload rated value A 8 10.5 13.6 18.5<br />

• with low overload rated value A 7.7 10.2 13.2 18<br />

• with high overload rated value A 5.9 7.7 10.2 13.2<br />

• maximum A 9.1 14 18 24<br />

Supplied active power at rated value of<br />

output voltage and at line voltage 400 V<br />

• with low overload kW 3 4 5.5 7.5<br />

• with high overload kW 2.2 3 4 5.5<br />

Supplied active power [hp] at rated<br />

value of output voltage and at line<br />

voltage 480 V<br />

• with low overload hp 4 5 7.5 10<br />

• with high overload hp 3 4 5 7.5<br />

Pulse frequency kHz 4 4 4 4<br />

Efficiency 0.98 0.98 0.98 0.98<br />

Power loss maximum 1) kW 0.126 0.138 0.181 0.245<br />

Cooling air flow<br />

m³/s 0.005 (635.66406) 0.005 (635.66406) 0.0092 (1169.62187) 0.0092 (1169.62187)<br />

(ft³/h)<br />

1 m measuring surface sound pressure dB 55 63 63 63<br />

level maximum<br />

Input current at line voltage 400 V<br />

• with low overload rated value A 6.9 9.75 12 17<br />

• with high overload rated value A 5.29 7.36 9.27 12.47<br />

for mains supply line<br />

• Type of electrical connection Screw-type terminals Screw-type terminals Screw-type terminals Screw-type terminals<br />

• Number of connections 1 1 1 1<br />

• Connectable conductor cross-section mm² 1.5 ... 2.5 6...16 6...16 6 ... 16<br />

• Connectable conductor cross-section 18 ... 14 10 ... 6 10 ... 6 10 ... 6<br />

(AWG)<br />

for motor supply line<br />

• Type of electrical connection Screw-type terminals Screw-type terminals Screw-type terminals Screw-type terminals<br />

• Number of connections 1 1 1 1<br />

• Connectable conductor cross-section mm² 1.5 ... 2.5 6...16 6...16 6 ... 16<br />

• Connectable conductor cross-section<br />

(AWG)<br />

18 ... 14 10 ... 6 10 ... 6 10 ... 6<br />

Type of electrical connection for PE<br />

conductor<br />

Cable length for motor<br />

On housing with<br />

M4 screw<br />

On housing with<br />

M4 screw<br />

On housing with<br />

M4 screw<br />

On housing with<br />

M4 screw<br />

• shielded maximum 2) m(ft) 150 (492.12598) 150 (492.12598) 150 (492.12598) 150 (492.12598)<br />

• unshielded maximum 2) m(ft) 300 (984.25197) 300 (984.25197) 300 (984.25197) 300 (984.25197)<br />

Dimensions<br />

•Width mm (in) 73 (2.87402) 100 (3.93701) 100 (3.93701) 100 (3.93701)<br />

•Height mm (in) 232 (9.13386) 275 (10.82677) 275 (10.82677) 275 (10.82677)<br />

•Depth mm (in) 209 (8.22835) 209 (8.22835) 209 (8.22835) 209 (8.22835)<br />

Frame size FSA FSB FSB FSB<br />

Weight, approx. 3) kg (lb) 3.2 (7.05478) 5.83 (12.85293) 5.83 (12.85293) 5.83 (12.85293)<br />

1) Typical values. More information can be found on the Internet at<br />

https://support.industry.siemens.com/cs/document/94059311<br />

2) The values apply without compliance to the EMC category.<br />

For more information, see Maximum permissible motor cable lengths<br />

SINAMICS G120X and on the Internet at<br />

www.siemens.com/sinamics-g120x/documentation<br />

3) The values apply for converters without integrated line filter.<br />