Motor Components (Options)<br />

Encoders<br />

4.2.3 Absolute encoder<br />

Function:<br />

• Angular measuring system to impress current<br />

• Speed actual value sensing<br />

• Absolute measuring system for the position control loop<br />

Table 4-6: Technical data, absolute encoder<br />

Features<br />

Absolute encoder<br />

EnDat (A–2048)<br />

Absolute encoder<br />

EnDat (A–512)<br />

Simple absolute<br />

encoder (A–32)<br />

Operating voltage 5V ± 5% 5V ± 5% 5V ± 5%<br />

Current consumption max. 300 mA max. 200 mA max. 300 mA<br />

Resolution, incremental<br />

(periods per revolution)<br />

2048 512 32<br />

Resolution, absolute<br />

(coded revolutions)<br />

4096 4096 4096<br />

Incremental signals 1 Vpp 1 Vpp 1 Vpp<br />

Serial absolute position<br />

interface<br />

EnDat EnDat EnDat<br />

Angular error ± 40" ± 80" ± 400"<br />

Note<br />

As a result of the reduced maximum operating temperature of absolute encoders with respect<br />

to incremental encoders, the thermally permissible rated motor torque is reduced by 10%.<br />

�����<br />

����<br />

� �<br />

Fig. 4-3 Output signals, absolute encoders<br />

�������������������������<br />

<strong>1FK7</strong> <strong>Synchronous</strong> <strong>Motors</strong><br />

4-6 <strong>Configuration</strong> <strong>Manual</strong> (PFK7), 10/2005 Edition, 6SN1197-0AD06-0BP1<br />