Gearboxes 5<br />

5.1 Selecting/dimensioning gearboxes and important parameters/<br />

quantities<br />

5.1.1 Overview<br />

• If the gearbox oil is in contact with the motor flange, then suitable shaft and flange seals<br />

must be selected.<br />

• Technical data should be taken from the Catalogs of the gearbox manufacturers.<br />

• The following influencing parameters should be taken into consideration:<br />

- Accelerating torque, continuous torque, number of cycles, cycle type, permissible input<br />

speed, mounting position, torsional backlash, torsional stiffness, radial and axial forces.<br />

- Worm gearboxes are only conditionally suitable for reversing operation with servo<br />

applications<br />

5.1.2 Dimensioning for S3 duty for natural cooling<br />

When engineering geared drive systems you can use the motor characteristic without reduction.<br />

Carefully observe the permissible maximum torque and the maximum permissible input<br />

speed of the gearbox.<br />

Mmot = Mout / (i • ηG )<br />

The motor and gearbox are assigned as follows:<br />

Mmax , gear ≥ M0(100K) • i • f<br />

Mmax, gear Max. permissible output torque<br />

M0(100K) Motor stall torque<br />

I Gear ratio<br />

f Supplementary factor<br />

f = f1 • f2<br />

f1 = 2 for motor accelerating torque<br />

f2 = 1 for ≤1000 gearbox switching cycles<br />

f2 > 1 for > 1000 switching cycles (refer to the Gearbox Catalog)<br />

<strong>1FK7</strong> <strong>Synchronous</strong> <strong>Motors</strong><br />