Key Article ▪ New Monte Rosa Hut SAC<br />
Structural Elements<br />
It is certainly unusual for the lower storeys to be built in<br />
timber. In this case all structural elements are constructed<br />
to have a fire resistance of 60 minutes. All surfaces are<br />
coated with non-cumbustible lining. The same applies to<br />
the staircase. The gro<strong>und</strong> floor is also provided with a fire<br />
resistance 60 minutes. In the dining room however the surfaces<br />
are flammable.The fire compartments of the storeys<br />
with guest rooms have a fire resistance of 30 minutes with<br />
flammable surfaces. All insulation in the building is made<br />
with non combustible materials having a melting point of<br />
over 1000 degrees Celsius.<br />
46 ▪ D-<strong>BAUG</strong> Annual Report 2009<br />
Fire Test on Glazing system<br />
In order to keep the staircase free of fire and smoke in the<br />
event of a fire, the glazing in this area is furnished with E30<br />
windows. The stud-and-tie system using aluminium in<br />
combination with a triple fire protection glazing was not<br />
available with the corresponding certificates of approval .<br />
Thus a fire test, which was successful, was carried out at<br />
the EMPA in Dübendorf <strong>und</strong>er the supervision of Thomas<br />
Nussbaumer to obtain a object-specific approval by the fire<br />
authorities.<br />
Fig. 3: Fire resistance test on a window at the EMPA Dübendorf (Photo: Hansbeat Reusser, Holzbaubüro).