Remote Control System<br />

type AT<strong>2000</strong> <strong>PCS</strong><br />

EC4811, PTO ready<br />

Closed contact = Engine running<br />

in Constant Speed mode and within<br />

the nominal rpm range.<br />

EC4813<br />

PTO out of service request<br />

Closed contact = request start of<br />

<strong>Diesel</strong> generator to take over load.<br />

Always required for two-stroke engines.<br />

Fig 16: Interface for a PTO solution<br />

MSB / SG (PTO)<br />

ET4810<br />

Shaft Generator breaker closed<br />

Closed contact = breaker closed<br />

ECS4824<br />

PTO in service request<br />

Closed contact (pulse) = request<br />

Will select Constant Speed mode<br />

in <strong>PCS</strong><br />

ECS4825<br />

PTO out of service request<br />

Closed contact (pulse) = request<br />

Will select Constant Speed mode<br />

in <strong>PCS</strong><br />

Optional signals. Only required if selection<br />

of constant speed has to be done from<br />

the Power Management System<br />

ECS4812A Increase RPM<br />

Closed contact (pulse) = increase<br />

ECS4812B Decrease RPM<br />

Closed contact (pulse) = decrease<br />

Optional signals. Only required if SG<br />

frequency and load control has to be done<br />

from the Power Management System<br />

Optional signal.<br />

Always required for two-stroke engines.<br />

<strong>Alphatronic</strong> <strong>2000</strong> <strong>PCS</strong> Propulsion Control System<br />