Electric horse tooth rasp<br />
Use<br />
6.3 Activities prior to use<br />
6.3.1 Function check residual current circuit breaker<br />
Fig. 15<br />
Fig. 16<br />
DANGER!<br />
Risk of injury due to electric current!<br />
If the residual current circuit breaker is not fully<br />
operational or used incorrectly, components may<br />
become live due to malfunctions. Coming into<br />
contact with live components may cause injury.<br />
Therefore:<br />
– Do not operate the machine without a residual<br />
current circuit breaker.<br />
– Check if the residual current circuit breaker<br />
functions properly prior to every use.<br />
– Never operate the machine unless the residual<br />
current circuit breaker is fully functional.<br />
Proceed as follows to test the operability of the residual current<br />
circuit breaker before using the machine:<br />
1. Insert the residual current circuit breaker vertically into the<br />
power socket.<br />
2. Press the RESET button (1) on the residual current circuit<br />
breaker.<br />
The residual current circuit breaker is not operational unless<br />
� the control lamp (2) lights up red.<br />
3. Press the TEST button (1) on the residual current circuit<br />
breaker.<br />
The residual current circuit breaker is not operational unless<br />
� the control lamp (2) goes out and<br />
� a distinct switching noise can be heard.<br />
After the function test was completed successfully:<br />
4. Press the RESET button.<br />
The residual current circuit breaker is operational.<br />
28 2010-03-17