12.02.2013 Views

HiTec Zang GmbH -- Main Catalogue 2009/10

HiTec Zang GmbH -- Main Catalogue 2009/10

HiTec Zang GmbH -- Main Catalogue 2009/10

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>10</strong><br />

Standard Systems<br />

Automatic Laboratory Reactor Systems<br />

HiClave plants dispose of a modular construction.<br />

The standard systems depicted in the following<br />

represent the basis for pressure reaction systems<br />

suited for a multitude of applications. They are<br />

adjustable to the respective requirements and can<br />

be equipped with the offered additional modules and<br />

components.<br />

Pressure Reactor System with Gassing and Balancing<br />

<strong>10</strong> ml and 20 ml Reactors<br />

Equipment<br />

The <strong>10</strong> ml and 20 ml reactors have<br />

a cover with cap nut and a central<br />

media connection with four-way<br />

connector. The middle connection<br />

of the four-way connector is<br />

allocated with the interior<br />

temperature sensor, the lateral<br />

ones usually with media connection<br />

and the manometer.<br />

The reactors tempered with a<br />

magnetic heating stirrer with<br />

heating block and agitated by a<br />

kinetic stirring rod.<br />

� Simple heating and stirring via a magnetic<br />

heating stirrer and a heating block attachment<br />

� Temperature Sensor (Pt<strong>10</strong>0)<br />

Pressure Reactor 20 ml, heated and agitated with Magnetic<br />

Stirrer; on the right: Reactor with fibre-optic ATR Sensor<br />

Connection Options<br />

� 1 x Temperature Sensor<br />

� 1 x Pressure Gauge<br />

� 1 x Media Connection<br />

Options<br />

� Other Connection Assignments<br />

50 ml Reaktor<br />

The 50 ml reactor a<br />

cover with cap nut<br />

and 3 connections.<br />

One of these can be<br />

equipped with a<br />

magnetic stirrer drive.<br />

The stirrer is passed<br />

through eccentrically.<br />

The other two<br />

connections are for<br />

the thermal sensor<br />

and and the media<br />

feed. If the stirrer<br />

drive is omitted in<br />

favour of magnetic<br />

stirrer, the now free<br />

connection can now<br />

be freely assigned.<br />

The reactors are<br />

heated via a heating<br />

sleeve and stirred<br />

overhead. In this<br />

case, the cooling can<br />

be conducted via a<br />

plate cooler.<br />

Alternatively, it is<br />

possible to heat and<br />

stir with a magnetic heating stirrer and heating block.<br />

Equipment:<br />

� Heating via Heating Sleeve<br />

� Stirring via Magnetic Stirring Head<br />

� Temperature Sensor (Pt<strong>10</strong>0)<br />

Connection Options<br />

30 Years of Excellence in Lab Scale Technology · Over 1.000 Products around the Laboratory Reactor

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!