DIAGNOSTICS<br />

322<br />

DIAGNOSTICS<br />

Digital Multimeters<br />

BKP 700-1846<br />

■ Fluke ® 115 Multimeter<br />

Compact, true-RMS meter for field service technicians.<br />

The Fluke ® 115 is the solution for a wide variety of<br />

electrical and electronic testing applications.<br />

Features<br />

Resistance, continuity, frequency, capacitance and<br />

diode test<br />

Measures 10 A (20 A overload for 30 seconds)<br />

Large, white LED backlight to work in poorly-lit areas<br />

Compact ergonomic design for one-handed<br />

operation<br />

True-RMS for accurate measurements on nonlinear<br />

loads<br />

Min/max/average with elapsed time to record<br />

signal fluctuations<br />

CAT III 600 V safety rated<br />

■ Multimètre Fluke MD 115<br />

Multimètre à valeurs efficaces vraies compact pour technicien d’entretien.<br />

Le multimètre Fluke MD 115 est idéal pour une vaste gamme d’applications<br />

liées aux essais d’équipement électrique et électronique.<br />

Caractéristiques<br />

Vérificateur de résistance, de continuité, de fréquence, de capacité et de diode<br />

Mesure jusqu’à 10 A (surcharge de jusqu’à 20 A pendant 30 secondes)<br />

Rétroéclairage à DEL blanc pour travailler dans les endroits mal éclairés.<br />

De conception compacte et ergonomique pour une utilisation d’une<br />

seule main<br />

Valeurs efficaces vraies permettant de mesurer efficacement les charges<br />

non linéaires<br />

Enregistrement des fluctuations min./max./moy. et horodatage<br />

Cote de sécurité CAT III 600 V<br />

ULT 95640<br />

■ Ergonomic Handheld Multimeter<br />

Full control manual range selection. AC/DC Voltage measurement up to<br />

500 Volt, resistance measurement up to 2 M? , diode test, overload<br />

protection, integrated test leads. Keep sight of testing point while reading<br />

the display. Single hand range and scale selection while testing.<br />

Electrical Specifications:<br />

Accuracies: . . . . . . .± (% of reading + number of least significant digits),<br />

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .at 23° ± 5°C, less than 75% RH<br />

DC Voltage: . . . . . . . . . . . . . . . . . .2000mV, 20V, 200V, 500V: ±0.8% ±1<br />

Impedance: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 M?<br />

AC Voltage: . . . . . . . . . . . . . . . . . . . . . . . . . . . .200V, 500V: ±1.5% ±10<br />

Impedance: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .450 k?<br />

Resistance: . . . . . . . . . . . . .2000? , 20k? , 200k? , 2000k? : ±1.0% ±3<br />

DC Current: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .200mA: ±2.0% ±2<br />

Diode Test: . . . . . . . . .Test current: 1.0± 0.6mA / Test voltage: 3.2V MAX.<br />

■ Multimètre portatif<br />

Contrôle de sélection manuel. Lecture de courant continu et de courant<br />

alternatif jusqu’à 500 volts, mesure de résistance jusqu’à 2 M? , test de<br />

diode, protection de surcharge, sondes intégrées. Très facile de consulter<br />

l’afficheur tout en ayant un oeil sur le point de test. Facile de sélectionner<br />

les fonctions d’une seule main tout en effectuant le test.<br />

Spécifications électriques :<br />

Précision : . . .± (% de la lecture + nombre du chiffre le plus insignifiant),<br />

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .à 23° ± 5°C, moins de 75 % RH<br />

Courant continu (DC) : . . . . . . . . .2000mV, 20V, 200V, 500V : ±0,8% ±1<br />

Impédance : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 M?<br />

Conrant alternatif (AC) : . . . . . . . . . . . . . . . . . .200V, 500V : ±1,5 % ±10<br />

Impédance : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .450 k?<br />

Résistance : . . . . . . . . . . . .2000? , 20k? , 200k? , 2000k? : ±1,0 % ±3<br />

Ampérage du courant continu : . . . . . . . . . . . . . . . . .200mA : ±2,0 % ±2<br />

Test de diode : . . . . . . . . . . . . . . . . . . . . .Test d’ampérage : 1,0± 0,6mA /<br />

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Test de tension : 3,2V max.<br />

ULT 95640R Fuse 200 mA / 250V / Fusible 200mA / 250V<br />

ULT 95630<br />

■ Professional <strong>Auto</strong>motive Digital Multimeter<br />

This high speed unit with a state of the art backlit dual digital display and a<br />

40 segment, 128/sec refresh rate bar graph provides the professional<br />

technician with advanced diagnostic features: AC/DC voltage to 1000<br />

volts, AC/DC current to10 Amp, resistance measurements to 40M? . Duty<br />

cycle %. Frequency measurement up to 20KHz. Injector pulse width for<br />

both TBI and PFI systems. Inductive RPM for DIS, 2 and 4 stroke engines<br />

(also in dual display with other related measurements). Dwell for 1 to 12<br />

cylinders. Diode test function. Temperature measurements ranging from –<br />

20°C to 1000°C (-4°F to 1832°F). Alternator voltage ripple measurement<br />

with go-no-go alert. Audible and symbolic fault code detector for blink type<br />

code output, O2 sensor tester with numeric cross-count and symbolic<br />

waveform display of signal output. Relative mode. Record mode with max,<br />

min, max-min and average readout (sampling seed 20/sec). Crest mode<br />

for measurement of transient signals as short as 1 millisecond. 4<br />

selectable trigger levels with ±trigger slopes. Data storage function to<br />

memorize up to 18 values. Includes: test leads, alligator clips, protective<br />

holster, K-type temperature probe, inductive pick-up and carrying case.<br />

■ Multimètre professionnel pour automobile<br />

Ce multimètre haute vitesse avec écran à éclairage à contre-jour, affichage<br />

numérique double et histogramme à 40 segments mis à jour 128<br />

fois/seconde, procure aux techniciens professionnels les fonctions de<br />

diagnostic avancées. Tension CA/CC jusqu’à 1000 volts, courant CA/CC<br />

jusqu’à 10 ampères. Mesure de résistance jusqu’à 40M? . % de coefficient<br />

d’utilisation. Mesure de fréquence jusqu’à 20KHz. Temps d’injection pour<br />

système monopoint et multipoint. Régime moteur pour DIS, 2 et 4 courses<br />

(aussi en affichage double avec d’autres mesures reliées). Angle de<br />

saturation pour 1 à 12 cylindres. Test de diode. Mesure de température<br />

variant entre –20°C à 1000°C (-4°F à 1832°F). Mesure d’ondulation de<br />

tension des alternateurs avec alerte de défaillance. Détecteur de code de<br />

faute sonore et à affichage symbolique pour les sorties de code de type<br />

clignotant. Test de sonde à O2 affichant le décompte de bascule et<br />

ondulation symbolique de la sortie de signal. Mode relatif. Mode<br />

enregistrement avec lecture max, min, max-min et moyenne (taux<br />

d’échantillonnage: 20/sec). Mode crête pour mesurer les signaux<br />

transitoires aussi court qu’une milliseconde. Sélection de 4 niveaux de<br />

déclenchement avec pente ascendante ou descendante. Fonction de<br />

mémorisation des données jusqu’à 18 valeurs. Comprend: câbles d’essai,<br />

pinces alligator, sondes de températures, étui protectrice, capteur inductif<br />

et coffret de rangement.<br />

ULT 95630R Fuse / Fusible