ULT 95635<br />
■ <strong>Auto</strong>motive Digital Multimeter<br />
Fully automatic range selection with auto power off and data hold. AC/DC<br />
voltage to 600 Volts. AC/DC current to 10 amps. Resistance measurement<br />
to 400M? Duty Cycle %. Frequency up to 20 kHz. Injection pulse width<br />
measurement for both TBI and PFI. Inductive RPM for DIS, 2 and 4 strokes.<br />
Dwell measurements for up to 12 cylinders. Diode test. Audible continuity<br />
test. Relative zero mode. Records mode with Max, Min, Max-Min and<br />
average. 4 selectable trigger levels with ±trigger slopes. Includes: test<br />
leads, alligator clips, protective holster, inductive pick-up, temperature<br />
probe and carrying case.<br />
■ Multimètre digital pour automobile<br />
Sélection de gamme automatique avec mise hors fonction et mémorisation<br />
des données. Tension CA/CC jusqu’à 600 volts. Courant CA/CC jusqu’à<br />
10A. Lecture de résistance jusqu’à 40 M? % de coefficient d’utilisation.<br />
Fréquence jusqu’à 20kHz. Temps d’injection pour système monopoint et<br />
multipoint. Régime moteur pour allumage direct, 2 et 4 courses. Angle de<br />
saturation (Dwell) pour 1 à 12 cylindres. Test de diode. Test de continuité<br />
audible. Mode zéro relatif. Mode enregistrement avec lecture max, min,<br />
max-min et moyenne. Sélection de 4 niveaux de déclenchement avec pente<br />
ascendante ou descendante. Comprend: câbles d’essai, pinces alligator,<br />
sondes de températures, étui protectrice et coffret de rangement.<br />
ULT 95636<br />
DIAGNOSTICS<br />
Multimètres numériques<br />
■ <strong>Auto</strong>motive Digital Multimeter<br />
Full control manual range selection with auto power-off. AC/DC voltage to<br />
600 volt, DC current to 10 Amp, tachometer function (500 to 10,000<br />
RPM), dwell measurement (0° to 120°), temperature measurement (-40° to<br />
1000°C), resistance measurement to 2 M? , diode test, continuity test and<br />
has overload protection. Included: soft carrying case, test leads alligator<br />
clips and temperature probe.<br />
Electrical Specifications:<br />
DC voltage: . . . . . . . . . . . . . . .±0.25% ±2 digits, 1M? input impedance,<br />
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .600 V AC/DC Overload protection<br />
AC voltage: . . . . . . . . . . . . . .±1.5% ±5 digits, 450K? input impedance,<br />
. . . . . . . . . . . . . . . . . . . .40 to 200 Hz, 600 V AC/DC Overload protection<br />
Resistance: . . . . . . . .±1.0% ±3 digits, 250 V AC/DC Overload protection<br />
DC current: . . . . . . . .±2.0% ±5 digits, Internal 10A 250V fuse protection<br />
Diode test: . . . . . . . . . . .2.4 ±0.6 mA test current, 3.2 V max. test voltage<br />
Continuity test: . . .Audible indicator when circuit resistance is below 100?<br />
Temperature: . . . . . . . . . . . . . . . . . . . . .-40°C to 400°C (±7% + 3 digits)<br />
. . . . . . . . . . . . . . . . . . . . . . . . . . .400°C to 1000°C (±1.5% + 10 digits)<br />
■ Multimètre digital pour automobile<br />
Control manuel avec sélection complète et mise hors fonction<br />
automatique. Courant continu et alternatif de 600 volts, ampérage du<br />
courant continu de 10 Amp, mesure de régime (500 à 10,000 tr/min),<br />
échelle de l’angle de saturation (0° à 120°), mesure de température (-40° à<br />
1000°), mesure de résistance jusqu’à 2M? , test de diode, de continuité et<br />
protection de surcharge. Comprend : boîtier de rangement souple, câbles<br />
d’essais, pinces crocodiles et une sonde de température.<br />
Spécifications électriques :<br />
Courant continu : . . . . . . . .±0,25% ±2 chiffre, impédance d’entrée 1M? ,<br />
. . . . . . . . . . . . . . . . . . . . . . . . . . . .protection de surcharge 600 V AC/DC<br />
Courant alternatif : . . . . .±1,5% ±5 chiffres, impédance d’entrée 450K? ,<br />
. . . . . . . . . . . . . . . . .40 to 200 Hz, protection de surcharge 600 V AC/DC<br />
Résistance : . .±1,0% ±3 chiffres, protection de surcharge 250 V AC/DC<br />
Ampérage du courant continu : . . . . . . . . . . . . . . . . . .±2,0% ±5 chiffres,<br />
. . . . . . . . . . . . . . . . . . . . . . . . . . .protection interne du fusible 10A 250V<br />
Test de diode : . .2,4 ±0,6 mA test de courant, 3,2 V max. test d’ampérage<br />
Test de continuité : . . . . . . . . . . . . . . . .Signal sonore lorsque la résistance<br />
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .du circuit est inférieure à 100?<br />
Température : . . . . . . . . . . . . . . . . . .-40°C à 400° C(±0,7% + 3 chiffres)<br />
. . . . . . . . . . . . . . . . . . . . . . . . . . .400°C à 1000°C (±1,5% +10 chiffres)<br />
ULT 95636R Porcelain fuse 10 AMP / Fusible en porcelaine 10 AMP<br />
ULT 95637R Fuse 200 mA / 250V / Fusible 200mA / 250V<br />
DIAGNOSTICS<br />