Termocamino <strong>650</strong> - <strong>800</strong><br />

IMPORTANT:<br />

With the use of metal pipes, it is indispensable that they be insulated with a suitable material<br />

(coverings in insulating fibre resistant up to 600°C) to prevent deterioration of the masonry or of<br />

the counterplate.<br />

It is indispensable that the space between the upper part, the sides of the appliance, and the incombustible<br />

material deflector on the hood be constantly ventilated.<br />

For this reason, there must be an air intake from below<br />

(cool air inlet) and an outlet above (warm air outlet).<br />

The spaces for air circulation indicated in Picture 13 are<br />

the minimum requirements:<br />

Top:<br />

Base:<br />

minimum opening 1000 cm2<br />

minimum opening 750 cm2<br />

1000 cm<br />

2<br />

This will provide:<br />

• greater safety<br />

• an increase of heat produced by the circulation of<br />

air around the appliance.<br />

Attention: We recommend making the counterplate in fireretardant<br />

plasterboard with self-supporting metal frame, so<br />

that its weight does not bear on the aesthetic covering<br />

(marble).<br />

The heat breather grille (Picture 14 pos.6) is installed on<br />

the upper part of the hood at about 20 cm from the ceiling.<br />

It must always be installed, as its function is to allow the<br />

heat accumulated inside the hood (overpressure) to come<br />

into the room.<br />

Picture 13<br />

750 cm<br />

2<br />

min. 65 cm rear and lateral<br />

7. EXTERNAL AIR INTAKE IN THE INSTALLATION AREA DURING<br />

COMBUSTION<br />

To ensure efficient operation of the appliance, it is essential that the place of installation has sufficient air<br />

intake for combustion and for re-oxygenation of the room itself. This means that, by way of dedicated<br />

openings communicating with the outside, combustion air must be able to circulate even when the doors<br />

and windows are closed.<br />

(1) Insulating material<br />

(1) Isolante<br />

(2) Seal<br />

(2) Sigillare<br />

(3) Insulating (3) Rivestimento coating isolante with external provvisto<br />

aluminum di foglio sheet di alluminio esterno<br />

(4) Door Sportello for per cleaning pulizia<br />

(5) (5) External Presa aria air esterna intake<br />

(6) Heat drain grating<br />

(6) Griglia sfiato calore<br />

(7) Controcappa ignifuga<br />

(7) Fire-retardant counter-hood<br />

(8) Inclinazione Maximum massima inclination 45° 45°<br />

(9) Schermare le parti in legno<br />

con materiale isolante<br />

(9) Shield wooden parts with<br />

(10) Min. (10) distance Distanze between posteriori e Coating laterali<br />

and insert min min 6 cm 6 cm<br />

Picture 14<br />